current time.
2. Change the On time setting: push and hold the “ON” button for 2 seconds, the On
time will display and flash. Push the “ON” button to change the On time setting.
3. Change the Off time setting: push and hold the “OFF” button for 2 seconds, the
Off time will display and flash. Push the “OFF” button to change the Off time
setting.
Manual Override
1. Continuously On: push the “TIME/MODE” button till the Digit LED display
“O”.
2. Continuously Off: push the “TIME/MODE” button till the Digit LED display
“F”.
3. Timer control: push the “TIME/MODE” button till the Digit LED back to normal
time display.
Remote Temporary Override
1. Remote Temporary On: push the “ON” button on the remoter, the Digit LED
display “Io”. The output will be On temporarily for 12 hours. After 12 hours the
timer will return to the Timer Control mode.
2. Remote Temporary Off: push the “OFF” button on the remoter, the Digit LED
display “IF”. The output will be Off temporarily for 12 hours. After 12 hours the
timer will return to the Timer Control mode.
3. Bypass Remote Temporary Override: push the “TIME/MODE” button on timer
unit to change to Timer Control(Normal display), Continuously On(display “O”)
or Off(display “F”) mode.
Caution:
When used outdoors this timer must be plugged into a GFCI protected outlet to
provent shock hazard. Let the switch hang downward so moisture doesn’t accumulate
in the outlet. Install cord and unit above ground level with the receptacle in
downward minimum 1.5m above ground. Suitable for damp locations. Not for
water immersion or for use were directly exposed to water. Store indoors when not in
use.
DO NOT splice , repair or modify. Unplug when not in use. Fully insert plug. DO
NOT use damaged remote sets. Inspect periodically. Use within the electrical rating as
the specification. DO NOT plug more than a total 1,000 watts in this unit. If watts are
not marked on appliance, multiply ampere rating(on nameplate) by 125 to determine
equivalent watts. Add determined watts for each plugged-in appliance or lamp (sum
of watts on bulbs) to find total watts being used. Operating temperature range 30C