2.1.10 Volume diameter reset
When with empty diameter, the output frequency of wire retracting machine
indicates as FN. And when with full diameter, the output frequency of wire
retracting machine indicates as FF.
The output frequency with full diameter and empty diameter of wire retracting
machine is different greatly, in order to make the liner speed of wire retracting
machine and host in the same step as soon as possible, the volume diameter reset
is needed when wire retracting machine changes volume. And the external
terminal X6 should set as 39, this terminal is defined volume reset terminal with
EDS1100 Series inverter.
2.1.11 Drawing machine tension control
F3.00=1EDS1100 Series inverter is drawing machine tension control mode.
2.1.12 Control wiring
(1) Connect Jog switch with host X2(defined as jog).
(2) Connect external terminal start-up switch with host FWD terminal.
(3)Connect pull wire speed potentiometer with host machine+10VVCI and
GND.
(4) Connect host analog output A02 terminal and GND terminal with VCI
terminal and GND terminal of wire retracting machine.
(5) Connect tension bar potentiometer with +10V, CCI and GND terminals of
EDS1100 Series inverter.
(6) Other relative control signal.
3.1 EDS1100 Series inverter model No. and specification
EDS1100 Series inverter rated input power: 3 phase AC 380V;
Adaptable electric motor power range is 0.75~37kW;
Max.output voltage is the same as input voltage .
EDS1100 Series inverter model No. and rated output current show as attached
list 1-1:
Attached list 1-1 EDS1100 Series drawing machine inverter model No.
Model No.
Adaptable Motor
Rated power(kW)
Adaptable Motor
Rated voltage(V)
Rated output
current (A)
EDS1100-4T0007 0.75
3 Phase AC 380V
2.3
EDS1100-4T0015 1.5 3.7
EDS1100-4T0022 2.2 5.0
EDS1100-4T0037 3.7 8.5
EDS1100-4T0055 5.5 13