www.enc.net.cn/en Tel/Fax:86-755-26984485/26985120 Appendix 2 The manual of EDS1300 middle frequency inverter
164
F5.14
Frequency arriving
(FAR) checkout
scope
0.00-50.00Hz 0.01Hz 5.00Hz ○
F5.15
FDT1 (frequency
level) electric level
0.00-high limit frequency 0.01Hz 10.00Hz ○
F5.16 FDT1 lag 0.00-50.00Hz 0.01Hz 1.00Hz ○
F5.17
Analog output
(AO1) selection
0: output frequency(0-high limit frequency)
1: set frequency(0-high limit frequency)
2: output current(0-2×rated current)
3: output voltage(0-1.2×load motor rated voltage)
4: bus-bar voltage(0-800V)
5: PID provision (0.00-10.00V)
6: PID feedback (0.00-10.00V)
7: reserved
8: reserved
9: reserved
1 0 ○
F5.18
Analog output
(AO1) gain
0.00-2.00 0.01 1.00 ○
F5.19
Analog output
(AO1) offset
0.00-10.00V 0.01 0.00 ○
F5.20
Analog output
(AO2) selection
Same as F5.17 1 0 ○
F5.21
Analog output
(AO2) gain
0.10-2.00 0.01 1.00 ○
F5.22
Analog output
(AO2) offset
0.00-10.00V 0.01 0.00 ○
F5.23
DO terminal output
function selection
Same as F5.17 1 0 ○
F5.24
DO maximum
pulse output
frequency
0.1-20.0(max. 20KHz)Max. DO port output pulse
frequency corresponds to Max. value selected by
F5.23
0.1KHz 10.0 ○
F5.25
Set interior
counting value
reaches provision
0-9999 1 0 ○
F5.26
Specified interior
counting value
reaches provision
0-9999 1 0 ○
F5.27
Interior timer
setting
0.1-6000.0s 0.1 60.0 ○
F6-Swing frequency special function parameter group
Function
code
Name Set range
Min.
unit
Factory
default
Modifi
-cation
F6.00 Reserved
F6.01 Reserved
F6.02 Reserved
F6.03 Reserved
F6.04 Reserved
F6.05 Reserved
F6.06 Reserved
F6.07 Reserved