User's Manual

Alarm Information
28
2. Check if the RF cable or antenna feeder that is connected to the transmitter gets loose
or damaged. If yes, secure or replace the cable or antenna feeder.
3. If you fail to solve the problem, contact your local dealer for technical support.
When the VSWR falls within the normal range, the prompt message will disappear and
the Alarm Indicator will go out.
Low Forward Power Alarm
When the forward power is below the preset value, the Alarm Indicator will glow red and
the LCD display will give you the prompt message below:
Then the repeater may continue transmission or terminate it according to the detected
result.
You need to:
1. Check if the RF cable or antenna feeder that is connected to the transmitter gets loose
or damaged. If yes, secure or replace the cable or antenna feeder.
2. If you cannot solve the problem, contact your local dealer for technical support.
When the forward power is restored to its normal value, the prompt message will
disappear and the Alarm Indicator will go out.