Product Manual

FCAR Product Instruction Manual
30
Data stream recording and comparison function
FCAR smart diagnosis system supports the recording and saving of data stream, and it
can be viewed infinitely in [Data Review]. It also supports the comparison function of
data streams. When the vehicle is in good condition, the data stream can be collected
and stored so as to provide a data reference through the data stream comparison
function for the next test or encountering a vehicle with the same model.
How to record data stream
1) Click [Selection] function icon " " in the upper right corner, tick the parameter
items to be recorded in the pop-up window, and select [OK] to return;
2) Select the [Data Stream Recording] function icon " ", enter the stored file
name in the pop-up window (it is suggest that the file is named after the vehicle
information for easy reference), select [OK] to return;
3) Click [OK] to start recording, manually slide the touch screen slowly to the last
data column; click [Stop] button in the lower left corner to stop recording and
automatically save the data stream;
4) After the data stream is recorded, the system will automatically store it (tip: the
data stream can be stored for up to 2 minutes). The data stream stored can be