Specifications

GOODOCOM Technologies Confidential GOC-BA440 Specification
GOODOCOM Technologies Confidential 26
12.2 Recommended Operating Conditions
Operating Conditions
Min
Typical
Max
Operating
Temperature
-30°C / +85°C
Storage Temperature -40°C / +125°C
*The module is functional across this range of voltages. However, optimal RF performance specified in
the data sheet is guaranteed only for 3.2V <VBAT < 4.8V and -30°C to +75°C.
Table 11: Recommended Operating Conditions
13.Recommended Reflow Profile
Referred to IPC/JEDEC standard.
Peak Temperature :
260 10s
Number of Times : 2 times
Figure17: Solder Reflow Profile
14.PCB Layout Recommendation
14.1 Antenna
Antenna trace impedance should be adjusted to 50ohm.The area above (or under) the RF antenna trace
should be free from other traces.
15.0 HCI UART Lines Layout Guideline
The following HCI line routing must obey the following rule to prevent overshoot/undershoot, as