Electrical Grounding
Ground cable used for transmitting the current from site circuit or devices belongs to Electrical
Grounding. It includes the AC or DC power supply used for site power device, and lines or cables
for connecting site alarm or sensor.
RF Grounding
This type involves the grounding of useless RF energy. One example of RF Grounding is to use shielding
object to avoid or minimize the harmful RF energy from communication devices and cables.
The device must be installed in places which are easily accessible.
Lightning Protection Grounding
Providing adequate lightning protection is vital for ensuring a safe and reliable communication
site. RF cable, and AC or DC power cables must be protected in case of the lightning strikes when
lightning enters the site.
Even though the contents covered in site grounding technology and lightning protection are
not in the range of this manual, several excellent industrial power supplies complied with the
requirements of grounding and lightning protection exist in communication site.
Device Grounding
The repeater is equipped with ground screw which is on the rear of the power supply module and
used for connecting the repeater to the site ground. Correct grounding and lightning protection
should be made for all antenna cable, AC and DC power cables, to accord with the rules and
requirements above. If not, permanent damages to the radio equipments may be caused.
Mechanical Installation
This section introduces mechanical installation steps of HQT repeater. Various mounting methods
vary depending on different types of rack or cabinet selected for fixing the repeater.
Mounting the Repeater in a Rack or Cabinet
The repeater is shipped in a box; it must be moved to a rack or cabinet from the packing container
once arrived.
Note: The rack or cabinet must have guide rails and hole spacing, with EIA 48.3 cm (19 inch)
configuration.
The cabinet must have adequate ventilation and comply with the minimum standards listed below:
- Depth: 41.3 cm (16.25 inch)
- Width: 48.3 cm (19 inch)
- Height: 13.4 cm (5.25 inch)
- The two installation rails are 5 cm (2 inch) away from the front of the cabinet, and front installation
hole spacing is 2.25 inch (from center to center).
For more information about mounting the equipment in a cabinet, please contact the Technical
Support Department of Shenzhen HQT Science & Technology Co., Ltd.