User's Manual

14/20
Control Buttons Operation and Manual gain control (MGC)
There are 5 operation modes relative to the control keys:
• Press the "SET" key for more than 3 seconds
• Short press on the "SET" key
• Short press on the "DEC-" key
• Short press on "INC+" key
• Simultaneously press on the "DEC-" and "INC+" keys for more than 3 seconds
Since the booster has a self-adaptive smart automatic level control (ALC) and
isolation gain processing (ISO), most of the time manual adjustments are not
required to achieve good coverage. However, in some cases where the ALC or ISO is
working at a very high rate to adjust the gain and the Alarm or ISO LED is flashing
more than once a second, a manual adjustment might be desired.
• Briefly press "SET" key, and the LCD will switch to the next gain value and it will start to blink.
(Uplink or downlink gain for a different band).
• Press "INC+" key once shortly and the gain will increase by 1dB, Press "DEC-" once shortly and the
gain value will be reduced by 1dB.
• Press the "SET" key for more than 3 seconds, and the LCD will return to the fixed display mode.
When the LCD is in the fixed display mode, press the "SET" key for more than 3 seconds. It will go
into the "Gain Setting Mode" and make one of the gain values start to blink.
When the LCD is in the fixed display mode, press the "DEC-" and "INC+" key simultaneously for
more than 3 seconds, the booster will reset the gain to the default manufacturer settings.
When the LCD is in the alarm display mode, press the "SET" key and the LCD screen will turn on
to help with troubleshooting and display the alarm indication showing the affected band or
bands, press the "INC+" (or "DEC-") key will
Note: Above values displayed on the LCD are examples for Home 10K Plus, other models please refer to the data sheet.