User's Manual

34
mode.
Time-out Timer (TOT)
Limits the amount of time the radio user can continuously transmit on a channel. If the
user holds down the PTT longer than the preprogrammed limit, the radio automatically
stops transmitting. The TOT feature is null while in Emergency Mode.
Time-out Timer
If the user holds down the PTT longer than the preprogrammed limit, the radio
automatically stops transmitting, and generates a warning tone until the PTT is released.
TOT Pre-Alert Time
The radio will emit the Pre-Alert Tone at the programmed TOT Pre-Alert time.
TOT Re-key Time
This timer is used to prevent the user from re-keying the radio, for the TOT Re-key Time
set after the allowed transmit time has expired.
TOT Reset Time
If the time interval between two transmissions is less than the TOT Reset Time, they shall
be deemed as a continuous transmission.
Battery Save
This feature can be enabled by your dealer. The Battery Save feature is automatically
activated once no activity on the channel and no operation performed (no key press and
no knob selection) within the specified period.
Pressing any key or receiving a signal will restore the radio to normal operation and exit
from Battery Save.