TR850 DMR Repeater Instruction Manual II
TR850 DMR Repeater Instruction Manual Instruction Manual TR850 DMR Repeater We are very grateful for your purchasing TR850 produced by Kirisun Communications Co., Ltd. We believe TR850 can bring great convenience to your life and work. TR850 DMR repeater which always incorporates the advanced technology and exquisite craft, we hope that the quality and function of this product could make you feel satisfied.
TR850 DMR Repeater Instruction Manual Notice to User ◆ Please read this Instruction Manual carefully before any operation to this product. When you start to use the product, we deem that you have read this manual carefully. ◆ Please save this Instruction Manual in a safe place for inference in need. ◆ In order to preserve your rights and interests, please fill in the Warranty Card seriously and actually when you purchase this product, and ask for the valid purchasing certificate.
TR850 DMR Repeater Instruction Manual Safety Information In order to use the indoor digital repeater effectively, please read the following information. ◆ This product can only be maintained by the professional technicians. Do not disassemble the radio by yourself. ◆The repeater setting and mounting must be approved by the local Radio Management Departments. ◆Installing the antenna of repeater must be do well of lightning protection, otherwise life or property damage may be occurred.
TR850 DMR Repeater Instruction Manual Contents 1 1.1 2 2.1 2.2 2.2.1 2.2.2 2.3 3 3.1 3.2 3.3 3.4 3.5 3.5.1 3.5.2 3.5.3 4 5 6 7 Unpacking and checking .......................................................................................... 1 Standard Accessories .............................................................................................. 1 Radio Overview ....................................................................................................... 3 Power On/Off Button .......
TR850 DMR Repeater 1 Instruction Manual Unpacking and Checking Please unpack carefully and check all the items listed in the following table before discarding the packing material. If any damage or loss occurs during shipment, please contact your dealer. 1.
TR850 DMR Repeater Instruction Manual 2
TR850 DMR Repeater 2 Instruction Manual Radio Overview 3
TR850 DMR Repeater Instruction Manual No. Part Name 1 Handles 2 Frond Panel LED Indicators 3 Power Switch 4 GPS Antenna Connector 5 ACCY Connector 6 Network Connector(IP) 7 100-240V AC Cable Connector 8 GND Screw 9 Tx Connector 10 Fan 11 Cooler 12 RX Connector 13 13.
TR850 DMR Repeater Instruction Manual 2.1 Power On/Off Button Power on/off the repeater. 2.2 ACCY Connector 1 9 10 18 19 26 2.2.
TR850 DMR Repeater Instruction Manual PIN3 Undefined PIN4 GND PIN5 ACC_MAP_ID2: It is used for test. PIN6 ACC_MAP_ID1: It is used for test.
TR850 DMR Repeater 2.2.2 Instruction Manual PIN22 PRGM_IO_7, External high level signal input PIN23 Undefined PIN24 Undefined PIN25 Undefined External Connector Instruction The method to activate external PTT: Short connect the Pin17 with Pin22 of VGA to activate external PTT. It can test the transmitting signal of repeater. Test Analog Receiving: Short connect Pin5 with Pin22 of VGA.
TR850 DMR Repeater Instruction Manual 2.3 LED Indicators No.
TR850 DMR Repeater 3 Instruction Manual Basic Operations 3.1 Powering On/Off When the repeater is turned off, press the power switch " light " " to power on the repeater. Then the "is on. After the system working normally, the light " present working mode. Press "、" " indicates the to power off the repeater. 3.2 Voice and Data Transfer The receiving and transmitting frequency are different on the repeater.
TR850 DMR Repeater Instruction Manual development can be made through this port. 3.4 Warning When unusual situation happens, warning indicator light will be enlightened. For example, when Receiving Frequency unlocks, the warning light will flash once one second; Transmitting frequency unlocks, the warning light will flash once two seconds; When both transmitting and receiving frequency unlock, the alarm indicator will stay light on.
TR850 DMR Repeater Instruction Manual New:Add new channel information, repeater will create new channel configuration files, a default analog channel, and set the default configurations, Open: Open a configuration file that saved in the storage device. Save: Save the current channel configuration, in order to open the file conveniently next time. If a new created channel or a channel read from the repeater, when saving them, you need to select a new save path (similar with “save as”).
TR850 DMR Repeater Instruction Manual Work Alone:Work as single repeater, not networking with other repeaters. Connect Working Mode:If exceed one single repeater’s coverage, this mode enables the repeater to connect with other repeaters to expand the coverage. Group Call Hang Time:When a terminal radio initiates a group call, and no PTT presses, repeater shall hang on for a period of time.
TR850 DMR Repeater Instruction Manual Value Range:0~7000ms, stepping is 500ms, the default value is 4000ms. Calling Hang Time: When a call ends, the repeater will hang on for a period of time, during this time, when a terminal radio presses the PTT, no need to build connect again, just communicate directly. Value Range: 0~7000ms, the stepping is 500ms, the default value is 4000ms. Network Setting: When networking, different repeaters can address to build a connecting by setting the network parameters.
TR850 DMR Repeater Instruction Manual Standing Wave Ratio. Power Amplifier Protect Threshold: As long as the temperature is higher than the threshold value, it stops working , the default threshold value is 80℃ Fan Work Threshold: As long as the temperature is higher the threshold value, the fan starts working. The default threshold value is 45℃. Fan Stop Work Threshold:As long as the temperature is higher the threshold value, the fan stops working. The default threshold value is 35℃.
TR850 DMR Repeater Instruction Manual cannot communicate with each other. Value Range: The CTCSS ranges from 0~254.1Hz, the stepping is 0.1 Hz, default value is 67 Hz. CDCSS: If select CDCSS or –CDCSS, needs to select a CDCSS value, or the transmitter and receiver cannot communicate with each other. Value Range: 0~777(octal number), the stepping is 1, the default value is 023. Notes: 1. Squelch level only use for analog channel. 2. Mix channel cannot select CSQ, must select CTCSS, CDCSS or –CDCSS.
TR850 DMR Repeater Instruction Manual pop up a dialog box, shows“ Write data successfully”. When you try to write data, tick the option “Exit after finish”, when finish writing data, the dialog box will exit automatically. If not tick this option, users have to press “Exit” manually to close the box. Notes (1) When try to read data, have to check the network, make sure the program menu tick the “Network” option, make sure the IP on the tools bar is the IP of the repeater you are going to program.
TR850 DMR Repeater Instruction Manual below interface flashes back, maybe fail to open the serial port. Please check the serial port connectivity, or other program takes up the serial port. (4)if the update is finished, software will note that. Please don’t forget to switch the boot mode back to 1000. Upgrading the System (1)Boot mode should be 1000 while upgrading. Choose the system programs to be downloaded, and remove unnecessary components according to needs.
TR850 DMR Repeater 5 Instruction Manual Installation Guide (refit guide) Duplexer Installation (1)Disassembly:As the figure below, take off the 4 screws and 6 screws of two sides of the top cover, and then slightly open the top cover.
TR850 DMR Repeater Instruction Manual (2)Take off the two screws of duplexer baffle, remove the duplexer.
TR850 DMR Repeater Instruction Manual (3)Slightly loosen the two screws of fixed duplexer bracket on installed clapboard to the bracket, and do not too loosen. Refer to following figure.
TR850 DMR Repeater Instruction Manual (4)Fixed the duplexer tail screws to the duplexer bracket. Push the duplexer to the end three duplexer connection holes until the duplexer is locked. Then fasten the duplexer bracket and install screw. Refer to following figure.
TR850 DMR Repeater 6 Instruction Manual Frequently Asked Questions (FAQ) Can’t connect to the PC programming software The IP of repeater input is error in the programming software. Or the user forgets the IP of repeater. Can’t transfer Please confirm the frequency and the working mode of the radio is the same with the repeater.
TR850 DMR Repeater 7 Instruction Manual Recommend Duplexer Parameters Model SGQ-450 A / D Duplexer’Frequency Range(MHz) 380~520 Bandwidth(KHz) ±400 Frequency Spacing(MHz) 10 Insertion Loss(dB) <1.0 Isolation (dB) >80 Suppression(dB) >80 V.S.W.R <1.3 NormaI lmpedance(Ω) 50 Max Power Input(W) 30 / 50 Standard Termination N/BNC Dimensions(mm) 223×154×31.5 223×191×39 Weight(KG) 1.2 / 2.
TR850 DMR Repeater Instruction Manual FCC Statement: Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
TR850 DMR Repeater Instruction Manual L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada.
TR850 DMR Repeater Instruction Manual environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.This equipment should be installed and operated with minimum distance 1.0m between the radiator & your body. IC exposition aux radiations: Cet équipement est conforme avec IC les limites d'exposition aux rayonnements définies pour contrôlé environnement.