User's Manual

Table Of Contents
8. Customer Service
Set as Test Mode to proceed walk-test,pulse count set as 1,2 or 3
Do walk-test in opposite direction to confirm the boundary of both sides, Make sure the
detection centre pointing to the centre of protected area.
Make sure the detection centre at the proper place. Should properly adjust the detection
area if you can not get an ideal detection area.
Walk across the far edge of coverage area at the speed of 1 step/second(about0.75m/s)
The LED will flash for seconds then alarmas shown in the right figure
7. Walk test in coverage area:
After adjust the detection angle , should redo the walk test as above.
Please change TEST mode to NORMAL mode after the Walk-test .
4.DIP switch functions:
MC-235R can set three modes as follows:
Test ModeEmitting alarm signal once detector is triggered.
No time-lag between two emissions. Default mode
for installing test.
Power-saver modeDetect every 3 minutes. Send detection
signal of detector and battery status
Coding ModePress tamper switch for more than 3 seconds
and send an identification code to receiver.
MC-235R can choose 3 kinds of pulse as follows:
1-pulse Alarm 1-pulse.
2-pulse: Alarm 2-pulse
3-pulse Alarm 3-pulse (Factory defaul)
Higher pulse counting and lower catch performance
and can avoid false alarm
3
2
1
4
DIP
ON
Modes of DIP switch 3&4:
MODE
ON OFF TEST
OFF ON POWER-SAVER
OFF OFF CODING
3
4
1
2
MODE
1-Pulse
2-Pulse
3-Pulse
ON
ON
OFF
OFF
OFF OFF
Our products are very reliablebut for some special reasons, the working performance will be limited in certain range.
We here list some cases as follows
. The voltage of control panel is not stable . Low-voltage of the detector.
For any help please contact with our company and your could visit our website for more information.
Warning: We are not responsible for the problem caused by improper operation by users!
5. Coding method between detector and
control pane and tamper switch setting
Coding set
Install the batteryLED flasheswhen
the detector gets stable after seconds
press tamper switch for more than 3
seconds and detector will send a
wireless signal. If the control panel
receives the signal and get the response
sound then code successfully. Please
refer to control panel manual for details.
Push here to
coding set
6 . Detection distance adjustment and battery change
Pull out the base cover and change
battery. Please pay attention to the
positive and negative.
Polarity
Jumper
If short circuit of the jumper as shown
then tamper alarm function invalid
FCC WARNING
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate
the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This
equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
once detector
is triggered.
The detector checks its batteries conditions when the batteries in
low voltage then it will transmit signals to warning users to
replace the batteries. It only transmit once to warn users.