User's Manual

P/N 20101217-3
C The user also can enter address code manually, that will reduce error rate, set the control panel
at manual code mode , then enter the 9-digit code on the label of transmitter.
4 Testing magnetic switch parallel move magnetic stripe and inductor. MD-210R will send signal
once to the control panel, and the LED on the transmitter flick 5 times.
5 Fix the cover
4 Install follow the pictures
1.If not drill on the wall please use strong double side glue or other strong Bonding agent to fix the
magnetic stripe and transmitter on the right place.
2. Do not mount on the base-loose place, possible to be destroyed place or with strong magnetic
interference(eg.loudspeaker, high voltage cable)
Note
Choose short circuit place when
magnetic fix on the R side of
reed switch. The jumper jump to the
R side of contact pin.
When use as
detector, these
jumper keep
opening.
Choose short circuit jumper:when
magnetic fix on the L side of
reed switch. The jumper jump to
the L side of contact pin.
when use as transmitter, connect
the alarm terminal to the wired
terminal of the magnetic.
Wired terminal
When use as
transmitter,
these jumper
keep short
circuit.
6. Miscellaneous Comments
Our wireless products are very reliable and tested to high standards. However, due to low transmitting
power and limited range(required by regulatory authorities , there are some limitations to be considered.
it will course the panel to make alarm at any alarm situation, following are some common examples
1. voltage instability for the control panel;
2.under voltage of detector etc.
These problem are not so difficult to solve, if needing help please contact the supplier.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate this equipment.This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
4.1 Change battery
The working life of battery is about one year change battery when the signal between the detector and
control panel become weak.
1.Open cover;
2.Take out used up battery and put in new battery rightly;
3.Test battery, parallel move the magnetic from transmitter, then the control panel will make alarm
information.
4.2 Clean and fix the cover
The surface of the detector will be dusty when used for a long time, please use wet cloth to clean it.
5.maintance
Open loop is NO;
Close loop is NC.