User's Manual
Table Of Contents
- 1 Safety
- 2 General Product Description
- 3 Getting Started
- 3.1 Unpacking and Checking
- 3.2 Environmental Requirements
- 3.3 Connecting the ECG Leadwire
- 3.4 Installing the Batteries
- 3.5 Powering On the Unit
- 3.6 Understanding Touch Gestures
- 3.7 Basic Operations
- 3.7.1 Understanding the Screen Display Orientation
- 3.7.2 Browsing the Screen Display
- 3.7.3 Switching the Screen Display Orientation
- 3.7.4 Flipping the Landscape Display
- 3.7.5 Displaying the Quick Keys Area
- 3.7.6 Entering the Main Menu
- 3.7.7 Turning the Display Off
- 3.7.8 Turning the Display On
- 3.7.9 Unlocking the Screen
- 3.7.10 Acknowledging the Nurse Call
- 3.8 Using the Pouch
- 4 User Configurations
- 5 Patient Management
- 6 Alarms
- 7 Monitoring ECG
- 7.1 Introduction
- 7.2 Safety
- 7.3 Preparation for Monitoring ECG
- 7.4 Changing the ECG Settings
- 7.5 Understanding the ECG Display
- 8 Monitoring SpO2 (Optional)
- 9 Monitoring with the TD60 at the CS
- 9.1 Introduction
- 9.2 Physiological Alarms
- 9.3 ECG Monitoring
- 9.4 QT Monitoring
- 9.5 ST Monitoring
- 9.6 Arrhythmia Monitoring
- 9.7 SpO2 Monitoring
- 10 Configuring the TD60
- 10.1 Introduction
- 10.2 Maintenance Menu
- 10.2.1 Entering the Maintenance menu
- 10.2.2 Configuring the General Menu
- 10.2.3 Configuring the Alarms Menu
- 10.2.4 Quick Keys Menu
- 10.2.5 Configuring the Defaults Menu
- 10.2.6 Transferring a Configuration
- 10.2.7 Screen Lock Menu
- 10.2.8 Changing the Passwords
- 10.2.9 Changing the Device Name
- 10.2.10 Demo Mode
- 10.2.11 Service Menu
- 11 Battery
- 12 Troubleshooting
- 13 Cleaning and Disinfecting
- 14 Maintenance
- 15 Accessories
- A Product Specifications
- B EMC
- D Symbols and Abbreviations
- E Anomaly
Product Specifications Mindray Patient Area Network (PAN) Specification
TMS60 Operator’s Manual A - 9
A.7 Mindray Patient Area Network (PAN) Specification
A.7.1 Technique Specification
A.7.2 Implemented Function
The function implemented by the Mindray PAN is transferring the configuration
between the transmitters.
A.7.3 Function Specification
Protocol standard
Mindray PAN low energy 4.0
Debugging mode
GFSK
Work frequency
2400 MHz to 2483.5 MHz
Channel interval
2 MHz
Wireless baud rate
1 Mbps
Output power
≤ 1 mW
Data Security
128 bit AES
Data integrity
Code error ≤ 1%
Data latency
Total delay of data transmission between the transmitters: ≤ 1
second
Priority
All communication data type shall have the same priority.
Transmission distance
Distinct vision distance between the transmitters is greater than
or equal to 3 m.
System capacity
10 m
2
space can hold 10 transmitters at the same time.
Resistance to wireless interference
When the distance between the wireless device at the
frequency of 2.4 GHz (including cellular mobile communication
networks, microwave ovens, cordless phones, and other
devices) and the transmitter is one meter, the Mindray PAN
communication functions are normal.
Communication interruption alarm
After the Mindray PAN communication between the
transmitters is interrupted, the transmitter prompts that the
communication is failed.