User's Manual

TEL: +86-755-8886 8480 FAX: +86-755-2982 5342 EMAIL: sales@minewtech.com URL: wwwminewtech.com
Page 4
Minew Technologies
Bluetooth 4.0 Module
Instructions V1.0
3. Set Disconnection Time (Command code: 0x03)
The default disconnection time is disabled; the range is from 0 to 250 seconds.
0x01: 1 second, 0x02: 2 seconds, 0x03: 3 seconds...0x0A: 10 seconds…0x1E: 30 seconds…
If it is disabled, the corresponding command code is 88 02 03 [00] AA.
For example, let’s change the disconnection time to 10 seconds.
Then, the correct command code is 88 02 03 [0A] AA.
If the setting is successful, the BLE module will send back the command code 88 02 03 0A AA, and the LED2 will
flash one time. Otherwise, the setting was failure.
4. Set Transmission Power (Command code: 0x04)
The default transmission power is 0dBm; the range is from -20dBm to +4dBm.
Please refer to the below table.
Transmission Power Value
Transmission Power Value
+4dBm 0x01 -8dBm 0x04
0 0x02 -12dBm 0x05
-4dBm 0x03 -20dBm 0x06
For example, let’s change the transmission power to -8dBm.
Then, the correct command code is 88 02 04 [04] AA.
If the setting is successful, the BLE module will send back the command code 88 02 04 04 AA, and the LED2 will
flash one time. Otherwise, the setting was failure.
5. Query Module Name (Command code: 0x11)
Command Code: 88 04 11 AA AA.
If the command is executed successful, the module will send back the command code 88 04 11 [41 42 43 44] and
the LED2 will flash one time. Otherwise, the command was failure.
5. Query Broadcasting Time (Command code: 0x12)
Command Code: 80 02 12 AA AA.
If the command is executed successful, the module will send back the command code 88 02 12 [xx] AA and the