User's Manual

TEL: +86-755-8886 8480 FAX: +86-755-2982 5342 EMAIL: sales@minewtech.com URL: wwwminewtech.com
Page 5
Minew Technologies
Bluetooth 4.0 Module
Instructions V1.0
LED2 will flash one time. Otherwise, the command was failure.
6. Query Disconnection Time (Command code: 0x13)
Command Code: 80 02 13 AA AA.
If the command is executed successful, the module will send back the command code 88 02 13 [xx] AA and the
LED2 will flash one time. Otherwise, the command was failure.
7. Query Transmission Power (Command code: 0x14)
Command Code: 80 02 14 AA AA.
If the command is executed successful, the module will send back the command code 88 02 14 [xx] AA and the
LED2 will flash one time. Otherwise, the command was failure.
8. Query MAC Address which connected with BLE Module (Command code: 0x14)
Command Code: 80 02 15 AA AA.
If the command is executed successful, the module will send back the command code as following:
88 06 15 [xx xx xx xx xx xx ] AA, and the LED2 will flash one time. Otherwise, the command was failure.
DEMO APP (Android version)
1. Please set the BLE module to Data Mode (CMD=1, SLP=0);
2. Then, run the nRF UART demo APP on the smart phone (Android 4.3+) like below image;