User's Manual
TEL: +86-755-8886 8480                FAX: +86-755-2982 5342                  EMAIL: sales@minewtech.com                  URL: wwwminewtech.com   
Page  5 
  Minew Technologies 
Bluetooth 4.0 Module 
Instructions V1.0   
LED2 will flash one time. Otherwise, the command was failure. 
6. Query Disconnection Time (Command code: 0x13) 
Command Code: 80 02 13 AA AA. 
If the command is executed successful, the module will send back the command code 88 02 13 [xx] AA and the 
LED2 will flash one time. Otherwise, the command was failure. 
7. Query Transmission Power (Command code: 0x14) 
Command Code: 80 02 14 AA AA. 
If the command is executed successful, the module will send back the command code 88 02 14 [xx] AA and the 
LED2 will flash one time. Otherwise, the command was failure. 
8. Query MAC Address which connected with BLE Module (Command code: 0x14) 
Command Code: 80 02 15 AA AA. 
If the command is executed successful, the module will send back the command code as following:   
88 06 15 [xx xx xx xx xx xx ] AA, and the LED2 will flash one time. Otherwise, the command was failure. 
DEMO APP (Android version) 
1. Please set the BLE module to Data Mode (CMD=1, SLP=0);   
2. Then, run the nRF UART demo APP on the smart phone (Android 4.3+) like below image;   








