User's Manual

Default Setting: 2.
2. On/Off Duration
This parameter can be determined how long the associated devices should stay ON
status. For instance, this parameter is set to 30(second), the PIR detector will send a
BASIC SET Command to an associated device with value basic set level if PIR
detector is triggered and the associated device will be turned on 30(second) before it
is turned off. This Parameter value must be large than Parameter 6#.
Function: On/Off Duration Setting
Parameter Number: 2
Parameter Size: 2 Byte
Available Settings: 5 - 600(second)
Default Setting: 30
3. Basic Set Level
Basic Set Command will be sent where contains a value when PIR detector is
triggered, the receiver will take it for consideration; for instance, if a lamp module is
received the Basic Set Command of which value is decisive as to how bright of dim
level of lamp module shall be. This
Parameter is used to some associated devices.
Function: Basic Set Level
Parameter Number: 3
Parameter Size: 1 Byte
Available Settings0, 1- 99 or 255
0 OFF, Alarm cancelling or turning a device off
1 - 99 or 255
ON (Binary Switch Device
Dim Level (Multilevel Switch Device
Default Setting: 99
4. PIR Detecting Function Enabled/Disabled
This parameter can be enabled or disabled the PIR detector detecting function.
Function: Enabled/Disabled PIR Function
Parameter Number: 4
Parameter Size: 1 Byte
Available Settings0 or 255
0 Disable PIR Detector Function
255 Enable PIR Detector Function
Default Setting: 255
5. Ambient illumination Lux Level (Not Complete, Reserved)
This parameter can be set a lux level value which determines when the light sensor is