User's Manual

S-8600 UHF RFID Reader User Manual
UHF RFID User Manual
In demo supplied, we could operate as below:
First, inventory tags in Buffer Mode to get all tags’ EPC NO.
Second, get buffer.
Third, back to the interface of Access tags and choose the EPC NO. which you want ,
as illustrated below:
When the choose completes, click on Select and the following screen displays:
We could see that the checkbox on the left for Selected Tag has been selected, the
Selected EPC NO. displays in the text box on the left.
Next, all the operations are only for the tag with this EPC NO.
If you want to cancel the match of EPC, just deselect the checkbox for Selected Tag, as
below:
2.4.6 Error Display Might Be Returned
There will be some warning of error if we did wrong operations in the process of
accessing tags.
Inventory Success, access failure:
Actually there are two-steps to access tag: first inventory tag, second access tag. Prompt
in the above image means inventory tag successfully, but can’t access.
Generally, there are two reasons lead to this problem. One is the parameter settings are
incorrect, for example, read a storage area not exist. The other reason is RF energy is not
enough, distance of access tab is about 60%-70% distance of inventory tag, so please