SIBO Q898X ACS Manual ACS software don't need to install on a Windows server, just add the android monitor to your network and it is accessed through a web portal inside your network. If you want to develop your own software, please contact info@sibochina.com.cn for API documents.
Content 1. Android Monitor Process………………………………………………………………………………………………………………………………………………………………………….......1 1.1 Connect WIFI…………………………………………………………………………………………………………………………………………………………………………………………………1 1.2 Set Time…………………………………………………………………………………………………………………………………………………………………………………………………..……1 1.3 Install App………………………………………………………………………………………………………………………………………………………………………………………………..……1 2. Web Server Connection……………………………………………………………………………………………………………………………………………….…………………………………1 3.
1. Android Monitor Process 1.1 Connect WIFI There is no touch on the screen, so you need to connect the monitor with a USB mouse. Right key of the mouse is return function and you can exit from ACS software and go to Settings->WIFI and connect with your network. You can also connect with lan port for Ethernet network and static network is suggested for fixed IP address. 1.2 Set Time Go to Settings-> Time & Date, you can choose your time zone and synchronize with the network. 1.
monitor. On the bottom left side of access control software, you will see the MAC address and IP address of android monitor. For example, MAC: 8CFCA003C597, IP address: 192.166.1.179 Then you go to a computer in the same intranet and open the web browser and input http://192.166.1.179:8080 And go to the web server page to make configuration or records check or camera monitor. Please note that your devices’ MAC address and IP address are different. P.S.: 8080 is the port number of server.
Please make sure the android monitor is working when you log in the web server. 3. Configuration access control software: When you make configuration on the web server, you need click on UPDATE TO Device, press Sure on the pop up window which appears on the top of screen and then reboot android monitor to make the configuration effects. When you reboot android monitor, you need to re-login your web server. 3.
Take Pictures: If you want to take photos when body temperature is tested, please tick on Take Picture, otherwise, there is no photo record in the Scan Records.
Note: Flow control and RS232 are under development now. Staff Access Password: When you set staff access password, you can use this password to re-login server, and then you will only see 4 functions of Access Register, Bulk access register, Temperature scan records, Camera monitor.
3.2 Access register You can upload the employees’ ID number and photos. Please upload photo files in JPG or PNG format, and the resolution is around 500x600, size is less than 500kb, and the registered photo request front face with no hair hide the eyes. The ID card number is unique for each employee. You can not register the same ID card number twice.
The stranger’s ID number is Unknown. When you enable taking photos, the android monitor will make a screenshot for every allowed persons. When you want to see the photo in full size, you can click on the right key for the selected picture and choose see the photo in new label page. 3.3 Add bulk upload function When you want to bulk upload register information, you need to login with Guest Account. Below video shows how to login with Guest Account: https://youtu.
3.4 Text Speech Settings There are three language for voice notification, you can choose from English, Spanish, Italian, French. But the displayed words can be only in English. You can configure speech text as you want. Flow control and welcome after face recognition are disabled. When you tick on Check wear mask and input sentences, but you won’t hear the voice notice, please check whether you tick on MASK CHECK from APP Portfolio. 3.
15:54 2020/5/19 16:51 2020/5/19 16:52 2020/5/19 16:53 36.8 245280375 GP undefined 1589878284419.png 36.6 245280375 GP undefined 1589878326269.png 36.5 245280375 GP undefined 1589878428505.png Photo needs to check from web server, from excel file you can not view photos. When you click on Delete All Record and Picture, all record information includes the photos will be deleted both in web server and in android monitor. 3.6 Camera Monitor It is live video stream.
3.8 Black body calibration There is a button of Black body calibration, it is for our tester and engineers to test and calibrate, normally it won't be used by any clients. 4 FAQ: 1. Why webpage shows “authorization is required to obtain data”? Please check whether your android monitor connects with network. If you use wifi network, after rebooting android monitors, it may take minutes to connect wifi, or you check whether your wifi connects automatically.
5 Specification: Model Camera Screen Resolution 2 million pixels Type Binocular wide dynamic camera Aperture F2.4 Focusing distance 50-150cm White balance auto Photo flood light LED and IR dual photo flood light Size 8.0 inch IPS LCD screen Resolution 800×1280 Touch Not supported (optional support) CPU RK3288 quad-core (optional RK3399 six-core, MSM8953 eight-core) Processor Interface Q898X Storage EMMC 8G Network module Ethernet and wireless (WIFI) Audio 2.
Upgrade button Support Uboot upgrade button Wired network 1 RJ45 Ethernet socket Credit card reader None (optional IC card reader, ID card, ID card) Face Detection Supports detection and tracking of multiple people at the same time Function Face library Up to 30,000 1: N face recognition Support 1: 1 face comparison Support Stranger detection Support Identify distance Support configuration UI interface configuration Support Upgrade remotely Support Interface Interfaces include device
Visitors' temperature is normal and released Support directly Abnormal temperature alarm General parameters Power DC12V(±10%) Operating temperature 0℃~60℃ Storage temperature -20℃~60℃ Power consumption 13.5W(Max) Installation method Screwed by wall mount bracket Size Packing list Support (temperature alarm value can be set) Standard:274.24*128*21.48(mm) IC card / ID card:296.18*132.
20C