Quick Installation Guide

LED indicators
Get to know your device
Port/button
DescriptionStatusLED indicators
Power
Solid on
The device is powered on properly.
Off
The device is not powered on or not powered on properly.
PoE/LAN
Solid on
Blinking
Off
The port is connected properly, but no data is transmitted.
Data is being transmitted over the port.
The port is not connected, or not connected properly.
LED1, LED2, LED3
(Received signal
strength indicator)
Solid on/
Blinking
The Base Station is successfully bridged or connected to other devices.
Solid on: The Base Station works in AP, Repeater, P2MP or Router mode.
Blinking: The Base Station works in Client, Universal repeater or WISP mode.
Each LED indicator is set with a received signal strength value, which is the
threshold for the corresponding LED indicator to light up. You can judge the
connection quality through the status of these indicators. The default values are
shown below.
Off
GND
Reset
PoE/LAN
Port/Button Description
Grounding terminal.
Use a grounding cord and included grounding screw to connect
the grounding terminal to the earth or building for surge and
lightning protection.
Reset Button.
When the Power LED indicator lights solid on, hold down this button
for about 8 seconds, then release it when all the LED indicators light
up. The Base Station is reset successfully.
10/100/1000 Mbps auto negotiation port for both power input and
data transmission.
You can use an Ethernet cable (CAT5e or better Ethernet cable is
recommended) to connect this port and the PoE injector for power
supply. The length of the Ethernet cable should not exceed 60 meters.
Pole mounting
GND Reset PoE/LAN
PoE/LANResetGND
Caution
Adapter Model: BN060-P12024
Manufacture: SHENZHEN HEWEISHUN NETWORK TECHNOLOGY CO., LTD.
Input: 100 - 240V AC, 50/60Hz 0.3A
Output: 24V 0.5A
:DC Voltage
Base Station: AP mode
LED1, LED2 and LED3 are solid on.
MS-5AC 20: Client mode
LED1, LED2 and LED3
are blinking.
MS-5AC 1: Client mode
LED1, LED2 and LED3
are blinking.
Bracket mounting
Install the device
Grounding
Base Station
GND terminal
Grounding cord
Earth
PoE/LANResetGND
P2MP connection with Omni-directional antenna
Base Station: AP Mode
LED1, LED2 and LED3 are solid on
MS-5AC: Client Mode
LED1, LED2 and LED3 are blinking
Option 1: Automatic bridging (recommended)
Internet
ISP Network Base Station + Omni Antenna
P2MP Link Connection
Small Office
Residence
Internet Café
FAQ
Wireless Status
-65dBm
-116dBm
Signal Strength
Background Noise
Transmit/Receive Speed 867Mbps/867Mbps
Power
LED1/LED2/LED3
PoE/LAN
Package contents
Basestation x 1
Metal strap x 1
PoE injector x 1
Quick installation guide x 1
Power cord x 1
Grounding screw (PM3*6 mm) x 1
MS-5AC 1
MS-5AC 2
MS-5AC 20
You can change the values on the Wireless > Advanced page in the web UI of
the Base Station.
MS-5AC
PoE/LANResetGND
PoE
Base Station
PoE injector
PoE
PoE injector
For product or function details, please go to www.ip-com.com.cn.
No device is connected to the Base Station in a wireless manner, or the received
signal strength does not reach the minimum value (-90dBm by default) for any LED
indicator to light up.
4. Connect the other side of the RF coaxial cables to the
connectors of the antenna.
1. Use a screwdriver to loosen the metal strap by turning the screw
counter-clockwise.
2. Straighten out the end of the metal strap, and thread it through the
back of the Base Station. Then wrap the metal strap around the
pole, and tighten the strap by turning the screw clockwise using
the screwdriver.
3. Remove the plastic screw caps on the RP-SMA connectors of the
Base Station.
4. Connect one side of two RF coaxial cables (enclosed with the
antennas) to the RP-SMA connectors of the Base Station.
5. Connect the other side of the RF coaxial cables to the connectors
of the antenna.
Connect the GND terminal of the Base Station to a grounding
terminal conencted the earth or building to protect the Base Station
from overvoltage and overcurrent caused by lightning and ESD.
1. Connect one side of a grounding cord to the included grounding
screw.
2. Conenct the grounding screw to the GND terminal of the Base
Station, and tighten it.
3. Connect the other side of the grounding cord to the grounding
terminal connected to the earth or building.
2. Remove the plastic screw caps on the RP-SMA connectors of
the Base Station.
3. Connect one side of two RF coaxial cables (enclosed with the
antennas) to the RP-SMA connectors of the Base Station.
1. Press the handle on the mounting bracket, align the four hooks on
the rear panel of the Base Station with the four slots on the
bracket, and slide the Base Station to fix it onto the bracket.
The Base Station in AP mode can provide WiFi network, allowing
home users or small office users to connect to the WiFi network with
outdoor long range CPEs. The Base Station can work with some
IP-COM CPEs. MS-5AC is used for illustration here.
Q1: I cannot log in to the web UI of the Base Station by entering
192.168.2.1. What should I do?
A1: Try the following methods:
• Ensure that the Base Station has been connected to the power source
and the computer properly.
Ensure that the IP address of the computer is set to 192.168.2.X (X
ranges from 2 to 254 and is unused).
• Restore the Base Station to factory settings.
Stronger signal strength (-60 dBm is better than -70 dBm), less background
noise (-100 dBm is better than -90 dBm), and fast transmit/receive speed
lead to better bridging signal.
CE Mark Warning
This is a Class A product. In a domestic environment, this product may cause
radio interference, in which case the user may be required to take adequate
measures.
This equipment should be installed and operated with a minimum distance
20cm between the device and your body.
The mains plug is used as disconnect device, the disconnect device shall
remain readily operable.
NOTE: (1) The manufacturer is not responsible for any radio or TV interference
caused by unauthorized modifications to this equipment. (2) To avoid
unnecessary radiation interference, it is recommended to use a shielded RJ45
cable.
RECYCLING
This product bears the selective sorting symbol for Waste electrical and
electronic equipment (WEEE). This means that this product must be handled
pursuant to European directive 2012/19/EU in order to be recycled or
dismantled to minimize its impact on the environment.
User has the choice to give his product to a competent recycling organization
or to the retailer when he buys a new electrical or electronic equipment.
Operating Temperature:-30°C - 60°C
Operating Humidity: 10% - 90% RH, non-condensing
FCC Statement
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment
is operated in a commercial environment. This equipment generates, uses, and
can radiate radio frequency energy and, if not installed and used in accordance
with the instruction manual, may cause harmful interference to radio communi-
cations. Operation of this equipment in a residential area is likely to cause
harmful interference in which case the user will be required to correct the
interference at his own expense.
Operation is subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Radiation Exposure Statement
This device complies with FCC radiation exposure limits set forth for an
uncontrolled environment and it also complies with Part 15 of the FCC RF Rules.
This equipment should be installed and operated with minimum distance 20cm
between the device and your body.
Caution!
Any changes or modifications not expressly approved by the party responsible
for compliance could void the user's authority to operate the equipment.
This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.
Operating frequency: 5150-5250MHz, 5725-5850MHz
NOTE: (1) The manufacturer is not responsible for any radio or TV interference
caused by unauthorized modifications to this equipment. (2) To avoid
unnecessary radiation interference, it is recommended to use a shielded RJ45
cable.
For EU/EFTA, this product can be used in the following countries:
Declaration of Conformity
Hereby, SHENZHEN IP-COM Networks Co., Ltd. declares that the radio
equipment type BS9 is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following
internet address: http://ip-com.com.cn/en/ce.html
Operating Frequency: EU/5150-5250MHz (CH36-CH48)
EIRP Power (Max.): 22.98dBm
Operating Frequency: EU/5470-5725MHz (CH100-CH116, CH132-CH140)
EIRP Power (Max.): 26.98dBm
Software Version: V1.0.0.10
Q2: How to reset the Base Station?
A2: Note: Resetting the Base Station clears all settings, and you need to
configure it again.
Method 1: When the Power LED indicator lights solid on, hold down the
Reset button for about 8 seconds, then release it when all the
LED indicators light up. The Base Station is reset successfully.
Method 2: Log in to the web UI of the Base Station, choose Tools >
Maintenance, and click the Reset button.
Q3: How to check that the Base Station is under the best connection
status ?
A3: Method 1: Observe the signal strength LED indicators of the Base
Station. The connection quality reaches the best when the
LED1, LED2 and LED3 indicators of the Base Station light solid
on or blink.
Method 2: Log in to the web UI of the Base Station (the default IP address
is 192.168.2.1), check the bridging status in Status >
Wireless Status.
Q4. The automatic bridging fails. What should I do?
A4: Try the following solutions:
• Peer-to-peer bridging: If the peer-to-peer bridging fails, reset the Base
Station and CPE to factory settings, and try again.
• Peer-to-multiple peers bridging: After peer-to-peer bridging succeeds,
ensure that the rest CPEs are powered on within 30 minutes. If the
problem persists, reset the Base Station and all CPEs, and try again.
Q5. When the bridging succeeds, the LED1, LED2, and LED3 indicators
do not light up or only some of them do. What should I do?
A5: Try the following solutions:
• Place the Base Station and the CPE in an elevated location with few
obstacles nearby.
• Make slight direction adjustment of the Base Station by moving it
vertically and horizontally. Change the direction with an interval of 20 -
30 s each time in order to observe the change of LED1, LED2 and LED3
indicators until the best signal is received.
Step 1: Prepare a Base Station and 20 CPEs (MS-5AC), and put all
MS-5AC near the Base Station.
Step 2: Choose one MS-5AC to perform peer to peer bridging with
the Base Station.
1. Place the Base Station and the MS-5AC next to each other.
2. Remove the covers of the Base Station and MS-5AC, and use
Ethernet cables to connect their PoE/LAN ports to the PoE
ports of the PoE injectors.
3. Use the included power cords to connect the PoE injectors to
power sources. The PoE/LAN LED indicators of the Base
Station and MS-5AC light up.
About 1 minute later, when the LED1, LED2 and LED3 indicators of
the Base Station light solid on and those of the CPE keep blinking,
the automatic bridging succeeds. The DHCP servers of the Base
Station and MS-5AC are disabled. MS-5AC works in Client mode
and its IP address is changed to 192.168.2.2.
After the bridging succeeds, the DHCP servers of the CPEs are
disabled, and the IP addresses of CPEs working in Client mode
are all changed into 192.168.2.2.
Option 2: Manual bridging
Refer to the configuration procedures in Scenario 1: PtP
backhaul connection with dish antennas to set the Base
Station to the AP mode, and set all MS-5AC to Client mode.
Step 3: Within 30 minutes after the peer-to-peer bridging succeeds,
power other MS-5AC on.
Step 4: About 1 minute later, if the LED1, LED2, and LED3 of these
CPEs keep blinking, the bridging succeeds.
Tips
The Base Station can work with the dish, sector or other antenna (purchased separately). If you purchase the IP-COM antenna, or this
Base Station fits to the bracket of the antenna you purchased, you can choose bracket mounting to install the Base Station; otherwise,
you can choose pole mounting.
Tips
• Automatic bridging is only applicable when the Base Station
and CPE are in factory settings.
• Ensure that only the Base Station and one CPE are powered
on when performing peer-to-peer bridging. Otherwise, the
peer-to-peer bridging may fail.
• For peer-to-multiple peers bridging, perform peer-to-peer
bridging first, and then power on the rest CPEs within 30
minutes. Otherwise, the bridging may fail.
• It is recommended to bridge one Base Station to 20 CPEs at
most.
Reset
12V 1A
GND
PoE/LAN
-90dBm -80dBm -70dBm
Quick Installation Guide
5GHz 11AC 867Mbps Gigabit Basestation
B9
Copyright
© 2021 Shenzhen Tenda Technology Co., Ltd. All rights reserved.
Tenda is a registered trademark legally held by Shenzhen Tenda
Technology Co., Ltd. Other brand and product names mentioned herein
are trademarks or registered trademarks of their respective holders.
Specifications are subject to change without notice.
Technical Support
Shenzhen Tenda Technology Co., Ltd.
6-8 Floor, Tower E3, NO.1001, Zhongshanyuan Road, Nanshan
District, Shenzhen, China. 518052
USA hotline: 1-800-570-5892
Toll Free: 7 x 24 hours
Canada hotline: 1-888-998-8966
Toll Free: Mon - Fri 9 am - 6 pm PST
Hong Kong hotline: 00852-81931998
Global hotline: +86 755-2765 7180 (China Time Zone)
Website: www.tendacn.com
E-mail: support@tenda.com.cn

Summary of content (1 pages)