Specifications
Table Of Contents
- 1
- Applying development of unilateral communication
- Serial port intercommunication agreement
- Summarize
- Control command format of serial
- Set BaudRate
- Get Reader Version
- Set Relay
- Get Relay
- Set Output Power
- Set Frequency
- Read Param
- Set Param
- Read Auto Param
- Set Auto Param
- Select Antenna
- Restore factory settings
- Reboot
- Start/ stop automode
- Clear Memory
- Set Reader Time
- Get Reader Time
- Set Report Filter
- Get Report Filter
- Set Reader Network Address
- Get Reader Network Address
- SetReader MAC
- Get Reader MAC
- Report Now
- Get Tag Info.
- GetReaderID
- Command format of serial read-write tag
- Collection of operation command
- Electronic tag storage area and notes
- SDK software development
- SDK compose
- Design introduction
- Basic constant and figure
- Constant definition
- API function return code
- Data type definition
- Parameter figure in reader
- Function return code
- Control command function
- Connect reader
- Disconnection
- Set baud rate
- Read version
- Set output power
- Set operation frequency
- Read reader basic operation parameter
- Set reader basic operation parameter
- Read reader auto parameter
- Set reader auto parameter
- Select antenna
- Set relay state in reader
- Reboot reader
- Set time
- Get time
- Get record
- Delete all records
- Network command
- Set IP address for reader
- Get IP address in reader
- Set reader MAC address
- Get reader MAC address
- Read write ISO18000-6B function
- Identify tag ID number
- Identify selected tag ID number
- Read data block
- Write data block
- Slow write data block
- Set write protection
- Read write protection
- Read write ISO18000-6C function
- Identify EPC number of ISO18000-6C tag
- Read a block data
- Write a block data
- Set read write protection state
- FCC警告语大于20cm(1)
Serial port intercommunication agreement | VI-88TR development handbook
Return data: if command execution correct, return data is 4 bytes of version
number:
Byte0
Major version of
hardware
Byte1
Minor version of
hardware(hardware
version number is
to show reader
model number)
Byte2
Major version of
software
Byte3
Minor version of
software
For example: if model number of reader is Reader1102, software version
number is V1.5, then return packet is:
『F0H 07H 02H address 0BH 02H 01H 05H CheckSum』
2.2.3 Set Relay
Function: to set relay status for reader
Command code: 03H
Command parameter: 1 byte
Bit0=1
No1 relay on
Bit0=0
No1 relay off
Bit1=1
No2 relay on
Bit1=0
No2 relay off
And so on.
Command packet: 『40H 03H 03H K CheckSum』
Return data: if success, return data is null.
090909RevA|Page 15 of 97