Specifications

Table Of Contents
Serial port intercommunication agreement | VI-88TR development handbook
14 909.00 34 919.00
15 909.50 35 919.50
16 910.00 36 920.00
17 910.50 37 920.50
18 911.00 38 921.00
19 911.50 39 921.50
20 912.00 40 922.00
2.2.7 Read Param
Function: to read the operation parameter in reader written by last
command.
Command code: 06H
Command parameter: none
Command packet: 40H 02H 06H B8H
Return data: if command execution correct, return data is 32 bytes PAM
from setting command.
F0H 22H 06H PAM CheckSum
Command format with reader address:
Command code: 06H
Parameter of reader address: address
Command parameter: none
Command packet: 40H 03H 06H address CheckSum
090909RevA|Page 20 of 97