Specifications

Table Of Contents
Serial port intercommunication agreement | VI-88TR development handbook
Command code: 13H
Command parameter: 32 bytes PAM
Command packet: 40H 26H 13H PAM Check
Return data: if command execution correct, return data is null. If success,
return data of Read Auto Param is 32 bytes parameters with following
sequence.
F0H 02H 13H FBH
Command format with reader address:
Command code: 13H
Parameter of reader address: address
Command parameter: 32 bytes PAM
Command packet: 40H 27H 13H Address PAM Check
Return data: if command execution correct, return data is null. If success,
return data of ReadParam is 32 bytes parameters with following sequence.
F0H 03H 13H Address Check
32bytes parameters (1 parameter 1 byte):
Byte number Definition
1
Tag reading mode0-timing1-trigger
2
Tag storage timeunits. default 1. High.
3
Tag storage time
unit
s. default 1. Low.
4
0-10ms, 1-20ms, 2-30ms, 3-50ms, 4-100ms.
Default 2. Atumatically read tag once at intervals.
5
Tag storage quantitydefault 1. The quantity of read tag ID
090909RevA|Page 24 of 97