Specifications
Table Of Contents
- 1
- Applying development of unilateral communication
- Serial port intercommunication agreement
- Summarize
- Control command format of serial
- Set BaudRate
- Get Reader Version
- Set Relay
- Get Relay
- Set Output Power
- Set Frequency
- Read Param
- Set Param
- Read Auto Param
- Set Auto Param
- Select Antenna
- Restore factory settings
- Reboot
- Start/ stop automode
- Clear Memory
- Set Reader Time
- Get Reader Time
- Set Report Filter
- Get Report Filter
- Set Reader Network Address
- Get Reader Network Address
- SetReader MAC
- Get Reader MAC
- Report Now
- Get Tag Info.
- GetReaderID
- Command format of serial read-write tag
- Collection of operation command
- Electronic tag storage area and notes
- SDK software development
- SDK compose
- Design introduction
- Basic constant and figure
- Constant definition
- API function return code
- Data type definition
- Parameter figure in reader
- Function return code
- Control command function
- Connect reader
- Disconnection
- Set baud rate
- Read version
- Set output power
- Set operation frequency
- Read reader basic operation parameter
- Set reader basic operation parameter
- Read reader auto parameter
- Set reader auto parameter
- Select antenna
- Set relay state in reader
- Reboot reader
- Set time
- Get time
- Get record
- Delete all records
- Network command
- Set IP address for reader
- Get IP address in reader
- Set reader MAC address
- Get reader MAC address
- Read write ISO18000-6B function
- Identify tag ID number
- Identify selected tag ID number
- Read data block
- Write data block
- Slow write data block
- Set write protection
- Read write protection
- Read write ISO18000-6C function
- Identify EPC number of ISO18000-6C tag
- Read a block data
- Write a block data
- Set read write protection state
- FCC警告语大于20cm(1)
Serial port intercommunication agreement | VI-88TR development handbook
Byte number Definition
stored in reader memory. High.
6
Tag storage quantity:default 1. The quantity of read tag ID
stored in reader memory. Low.
7
Data output format
:
0-terse
,
1-standard
,
2-XML format.
Default0.
8
Output interface: 0-RS232, 1-RS485, 2-RJ45. Default 0.
3- Wiegand26, 4- Wiegand34.
9
Wiegand output pulse width, default40.
10
Wiegand output pulse interval, default200.
11
Set start bit of output tag ID, value 0
~
4. Default 0.
(Wiegand)
12
Set storage address of ID in tag(default0): 0-tag ID number
1-usder defined number(Wiegand)
13
Notify interval
:
unit
:
s. Default 1. Automatically notify host pc
once at intervals. Default 120s, 1~255.
14
Notify condition
:
default1. 0-notify now
,
1-timing
,
2-add
,
3-remove,4-change
15
Output port of notify (if no reading for long time, send EPC
number with length 0 to output port)
0—no use 1—use time depends on ”notify interval”.
16
Select antenna. 1-ant1,2-ant2,4-ant3,8-ant4
17
Set trigger mode(default0): 0-low level 1-high level
18
Host PC IP address1
19 Host PC IP address2
20 Host PC IP address3
21 Host PC IP address4
22 Host PC port -high
23
Host PC port -low
24
Null
25
Null
26
Null
27
Null
28
Null
29 Null
30
0-no alarm,
1-alarm. Detect alarm or not in timing and
trigger mode.
31
null
32
Control relay or not in Auto state. 0- no control 1- control
2.2.11 Select Antenna
090909RevA|Page 25 of 97