Specifications

Table Of Contents
Serial port intercommunication agreement | VI-88TR development handbook
Function: The parameters of the Reader device back to factory
Command code: 0EH
Command parameter: none
Command packet: 40H 02H 0DH Check
Return data: if success, return data is null.
F0H 02H 0DH Check
2.2.13 Reboot
Function: reboot reader, which equivalent to power on again after power off.
Command code: 0EH
Command parameter: none
Command packet: 40H 02H 0EH B0H
Return data: if success, return data is null.
F0H 02H 0EH 00H
Command format with reader address:
Command code: 0EH
Parameter of reader address: address
Command parameter: none
Command packet: 40H 03H 0EH address CheckSum
090909RevA|Page 27 of 97