Specifications

Table Of Contents
Serial port intercommunication agreement | VI-88TR development handbook
Command code: 12H
Command parameter: none
Command packet: 40H 02H 12H ACH
Return data: if success, return data is yy/mm/dd/hour/minute/second.
F0H 08H 12H yy mm dd hh ff ss CheckSum
Command format with reader address:
Command code: 12H
Parameter of reader address: address
Command parameter: none
Command packet: 40H 03H 12H address CheckSum
Return data: if success, return data is yy/mm/dd/hour/minute/second.
F0H 09H 12H address yy mm dd hh ff ss CheckSum
2.2.18 Set Report Filter
Function: read tag chosen from setted filter can be put into output list.
Command code: 15H
Command parameter1: 2 bytes of mask address ADDR, high digit before,
low digit after. That’s bit address.
Command parameter2: 2 bytes of mask length LEN, high digit before, low
090909RevA|Page 30 of 97