Table Of Contents
- 1
- Applying development of unilateral communication
- Serial port intercommunication agreement
- Summarize
- Control command format of serial
- Set BaudRate
- Get Reader Version
- Set Relay
- Get Relay
- Set Output Power
- Set Frequency
- Read Param
- Set Param
- Read Auto Param
- Set Auto Param
- Select Antenna
- Restore factory settings
- Reboot
- Start/ stop automode
- Clear Memory
- Set Reader Time
- Get Reader Time
- Set Report Filter
- Get Report Filter
- Set Reader Network Address
- Get Reader Network Address
- SetReader MAC
- Get Reader MAC
- Report Now
- Get Tag Info.
- GetReaderID
- Command format of serial read-write tag
- Collection of operation command
- Electronic tag storage area and notes
- SDK software development
- SDK compose
- Design introduction
- Basic constant and figure
- Constant definition
- API function return code
- Data type definition
- Parameter figure in reader
- Function return code
- Control command function
- Connect reader
- Disconnection
- Set baud rate
- Read version
- Set output power
- Set operation frequency
- Read reader basic operation parameter
- Set reader basic operation parameter
- Read reader auto parameter
- Set reader auto parameter
- Select antenna
- Set relay state in reader
- Reboot reader
- Set time
- Get time
- Get record
- Delete all records
- Network command
- Set IP address for reader
- Get IP address in reader
- Set reader MAC address
- Get reader MAC address
- Read write ISO18000-6B function
- Identify tag ID number
- Identify selected tag ID number
- Read data block
- Write data block
- Slow write data block
- Set write protection
- Read write protection
- Read write ISO18000-6C function
- Identify EPC number of ISO18000-6C tag
- Read a block data
- Write a block data
- Set read write protection state
- FCC警告语大于20cm(1)
Serial port intercommunication agreement | VI-88TR development handbook
into 256bytes. An address is for each byte, corresponding to 0~255.
Thereinto:
Address 0~7, 8 words(64bits): tag ID number. Fixed before product
leaves factory, can’t be modified.
Address 8~223: user information storage area, can be distributed at
discretion.
Address 224~255: write protection byte.
2.3.1.1 List Tag ID
Function: to list readable tag ID in antenna radiation field.
Command code: FEH
Command parameter: none
Command packet: 『40H 02H FEH C0H』
Return data: if success, byte count of return data = number of all listed tags
M(1byte)+ M*data of (tag length sent out L(<=8,1byte)+ 8(ID)).
『F0H 3+M*(L+8)FEH M M*(L+8)CheckSum』
Command format with reader address:
Command code: FEH
Parameter of reader address:address
Command parameter: none
090909RevA|Page 36 of 97