Command parameter4: 1byte addr, start address(unit:Word).
Command parameter5: 1byte len, length of data(unit:Word).
Command parameter6: len*2bytes written data.
Command parameter7: 4bytes, AccessPassword.
Command packet: 40H 10+L*2+len*2 EBH L EPC mem addr
len data AccessPassword CheckSum
Return packet: if success, return data is null.
F0H 02H EBH 23H
Note: AccessPassword is workable only when memory bank is
locked. When unlocked, writable without password. When
permanently locked, password is useless.
Command format with reader address:
Command code: EBH
Parameter of reader address:address
Command parameter1: 1byte L, digit count of EPC, to show the word count
of EPC number.
Command parameter2: L*2bytes EPC number, to show which tag data to
write.
Command parameter3: 1byte mem, select memory bank.
0 Password
1 EPC
090909RevA|Page 51 of 97