Specifications
Table Of Contents
- 1
- Applying development of unilateral communication
- Serial port intercommunication agreement
- Summarize
- Control command format of serial
- Set BaudRate
- Get Reader Version
- Set Relay
- Get Relay
- Set Output Power
- Set Frequency
- Read Param
- Set Param
- Read Auto Param
- Set Auto Param
- Select Antenna
- Restore factory settings
- Reboot
- Start/ stop automode
- Clear Memory
- Set Reader Time
- Get Reader Time
- Set Report Filter
- Get Report Filter
- Set Reader Network Address
- Get Reader Network Address
- SetReader MAC
- Get Reader MAC
- Report Now
- Get Tag Info.
- GetReaderID
- Command format of serial read-write tag
- Collection of operation command
- Electronic tag storage area and notes
- SDK software development
- SDK compose
- Design introduction
- Basic constant and figure
- Constant definition
- API function return code
- Data type definition
- Parameter figure in reader
- Function return code
- Control command function
- Connect reader
- Disconnection
- Set baud rate
- Read version
- Set output power
- Set operation frequency
- Read reader basic operation parameter
- Set reader basic operation parameter
- Read reader auto parameter
- Set reader auto parameter
- Select antenna
- Set relay state in reader
- Reboot reader
- Set time
- Get time
- Get record
- Delete all records
- Network command
- Set IP address for reader
- Get IP address in reader
- Set reader MAC address
- Get reader MAC address
- Read write ISO18000-6B function
- Identify tag ID number
- Identify selected tag ID number
- Read data block
- Write data block
- Slow write data block
- Set write protection
- Read write protection
- Read write ISO18000-6C function
- Identify EPC number of ISO18000-6C tag
- Read a block data
- Write a block data
- Set read write protection state
- FCC警告语大于20cm(1)
Serial port intercommunication agreement | VI-88TR development handbook
1 EEH To identify readable tag ID in antenna radiation field
based on mask condition
2 EDH To get listed tag ID by rfs_ListTagID command from
reader memory
3 ECH To read a block of data starting from
the appointed
address in appointed memory bank of appointed tag
4 EBH
To write data into the appointed address unit in
appointed memory bank of appointed tag
5 EAH
To set write protect for appointed memory bank of
appointed tag
6
E7H
To write EPC number into EPC memory bank of tag
7
8
9
10
2.4.2 ISO18000-6B command
Serial
number
Command Function
1
FEH
To list readable tag ID in antenna radiation field
2 FDH
To get listed tag ID by rfs_ListTagID command from
reader memory
3 FBH
To list readable tag ID in antenna radiation field
based on following parameter condition
4 F6H
To read a block of data starting from the appointed
address of appointed tag
5 F5H
To write data into the appointed address unit of
appointed tag
6 F4H
To set write protect for the appointed address unit of
appointed tag
7 F3H
To read
if the appointed address unit of appointed
tag is set write protect
8 F2H
To write data into the appointed address unit of
appointed tag
2.4.3 Other command
Serial
number
Command Function
1 01H To set operation baud rate for RS232 interface
090909RevA|Page 57 of 97