Specifications
Table Of Contents
- 1
- Applying development of unilateral communication
- Serial port intercommunication agreement
- Summarize
- Control command format of serial
- Set BaudRate
- Get Reader Version
- Set Relay
- Get Relay
- Set Output Power
- Set Frequency
- Read Param
- Set Param
- Read Auto Param
- Set Auto Param
- Select Antenna
- Restore factory settings
- Reboot
- Start/ stop automode
- Clear Memory
- Set Reader Time
- Get Reader Time
- Set Report Filter
- Get Report Filter
- Set Reader Network Address
- Get Reader Network Address
- SetReader MAC
- Get Reader MAC
- Report Now
- Get Tag Info.
- GetReaderID
- Command format of serial read-write tag
- Collection of operation command
- Electronic tag storage area and notes
- SDK software development
- SDK compose
- Design introduction
- Basic constant and figure
- Constant definition
- API function return code
- Data type definition
- Parameter figure in reader
- Function return code
- Control command function
- Connect reader
- Disconnection
- Set baud rate
- Read version
- Set output power
- Set operation frequency
- Read reader basic operation parameter
- Set reader basic operation parameter
- Read reader auto parameter
- Set reader auto parameter
- Select antenna
- Set relay state in reader
- Reboot reader
- Set time
- Get time
- Get record
- Delete all records
- Network command
- Set IP address for reader
- Get IP address in reader
- Set reader MAC address
- Get reader MAC address
- Read write ISO18000-6B function
- Identify tag ID number
- Identify selected tag ID number
- Read data block
- Write data block
- Slow write data block
- Set write protection
- Read write protection
- Read write ISO18000-6C function
- Identify EPC number of ISO18000-6C tag
- Read a block data
- Write a block data
- Set read write protection state
- FCC警告语大于20cm(1)
Serial port intercommunication agreement | VI-88TR development handbook
access password, and can be set to readable and writable from secured
state or permanently readable and writable or never readable and writable
later;
Permanently Readable and Writable—can be read and written without
access password, but can’t be set to readable and writable from secured
state or never readable and writable later;
Readable and Writable from secured state—can read and modify password
with access password only, and can be set to permanently readable and
writable or readable and writable from any state or never readable and
writable later;
Never Readable and Writable—can’t be read or write even if with access
password, can’t read or modify password forever.
Note: to set read and write protect for tag, must know access
password of tag in advance.
(2) Memory unit of ISO-18000-6B is devided into 2 memory banks.
Internal storage capacity is 2048bits, which is devided into 256bytes. An
address is for each byte, corresponding to 0~255.
Thereinto:
Address 0~7, 8 words(64bits): tag ID number. Fixed before product
leaves factory, can’t be modified.
Address 8~223: user information storage area, can be distributed at
discretion. Can be rewrited, and can be locked. Once locked, can’t be
rewrited again, and can’t be unlocked.
Address 224~255: write protection byte.