Specifications
Table Of Contents
- 1
- Applying development of unilateral communication
- Serial port intercommunication agreement
- Summarize
- Control command format of serial
- Set BaudRate
- Get Reader Version
- Set Relay
- Get Relay
- Set Output Power
- Set Frequency
- Read Param
- Set Param
- Read Auto Param
- Set Auto Param
- Select Antenna
- Restore factory settings
- Reboot
- Start/ stop automode
- Clear Memory
- Set Reader Time
- Get Reader Time
- Set Report Filter
- Get Report Filter
- Set Reader Network Address
- Get Reader Network Address
- SetReader MAC
- Get Reader MAC
- Report Now
- Get Tag Info.
- GetReaderID
- Command format of serial read-write tag
- Collection of operation command
- Electronic tag storage area and notes
- SDK software development
- SDK compose
- Design introduction
- Basic constant and figure
- Constant definition
- API function return code
- Data type definition
- Parameter figure in reader
- Function return code
- Control command function
- Connect reader
- Disconnection
- Set baud rate
- Read version
- Set output power
- Set operation frequency
- Read reader basic operation parameter
- Set reader basic operation parameter
- Read reader auto parameter
- Set reader auto parameter
- Select antenna
- Set relay state in reader
- Reboot reader
- Set time
- Get time
- Get record
- Delete all records
- Network command
- Set IP address for reader
- Get IP address in reader
- Set reader MAC address
- Get reader MAC address
- Read write ISO18000-6B function
- Identify tag ID number
- Identify selected tag ID number
- Read data block
- Write data block
- Slow write data block
- Set write protection
- Read write protection
- Read write ISO18000-6C function
- Identify EPC number of ISO18000-6C tag
- Read a block data
- Write a block data
- Set read write protection state
- FCC警告语大于20cm(1)
SDK software development | VI-88R development handbook
BYTE BaudRate; //(1)baud rate of serial, value:
00H~08H.
BYTE Power; //(2)RF power output, value:
20~30dBm.(0-63)
BYTE Min_Frequence; //(3)start point of transmitting
microwave signal frequency, value: 1~63.
BYTE Max_Frequence; //(4)end point of transmitting
microwave signal frequency, value: 1~63.
BYTE Reserve5; //(5)reserve, changed into modulation
depth later.
BYTE WorkMode; //(6)work mode of reader:0-Auto,
1-Command
BYTE ReaderAddress; //(7)RS485 address:0--255
BYTE NumofCard; //(8)max tags of once reading.
BYTE TagType; //(9)type of tag:01H-ISO18000-6B,
02H-EPCC1,04H-EPCC1G2,08H-EM4442。
BYTE ReadDuration; //(10)tag reading duration time:RF
emission duration time is only effective for EM tag; 0-10ms,1-20ms,2
-30ms,3-40ms.
BYTE ReadTimes; //(11)read times M:reader will execute
the command for M times when receiving reading command from host
computer.
090909RevA|Page 63 of 97