Specifications
Table Of Contents
- 1
- Applying development of unilateral communication
- Serial port intercommunication agreement
- Summarize
- Control command format of serial
- Set BaudRate
- Get Reader Version
- Set Relay
- Get Relay
- Set Output Power
- Set Frequency
- Read Param
- Set Param
- Read Auto Param
- Set Auto Param
- Select Antenna
- Restore factory settings
- Reboot
- Start/ stop automode
- Clear Memory
- Set Reader Time
- Get Reader Time
- Set Report Filter
- Get Report Filter
- Set Reader Network Address
- Get Reader Network Address
- SetReader MAC
- Get Reader MAC
- Report Now
- Get Tag Info.
- GetReaderID
- Command format of serial read-write tag
- Collection of operation command
- Electronic tag storage area and notes
- SDK software development
- SDK compose
- Design introduction
- Basic constant and figure
- Constant definition
- API function return code
- Data type definition
- Parameter figure in reader
- Function return code
- Control command function
- Connect reader
- Disconnection
- Set baud rate
- Read version
- Set output power
- Set operation frequency
- Read reader basic operation parameter
- Set reader basic operation parameter
- Read reader auto parameter
- Set reader auto parameter
- Select antenna
- Set relay state in reader
- Reboot reader
- Set time
- Get time
- Get record
- Delete all records
- Network command
- Set IP address for reader
- Get IP address in reader
- Set reader MAC address
- Get reader MAC address
- Read write ISO18000-6B function
- Identify tag ID number
- Identify selected tag ID number
- Read data block
- Write data block
- Slow write data block
- Set write protection
- Read write protection
- Read write ISO18000-6C function
- Identify EPC number of ISO18000-6C tag
- Read a block data
- Write a block data
- Set read write protection state
- FCC警告语大于20cm(1)
SDK software development | VI-88R development handbook
Input parameter:
szPort : character pointer directing at communication port, eg.『COM1』、
『COM2』……
nBaudRate: baud rate of serial, effective value is: 9600,19200,38400,
57600,115200.
Address: reader address.
Output parameter: to judge if connection success or failure reason
according to apiReturn value returned by function.
hScanner : reader handle
connection via Ethernet port
apiReturn _stdcall Net_ConnectScanner(SOCKET *hSocket,char
*nTargetAddress,UINT nTargetPort,char *nHostAddress,UINT nHostPort);
Function: to establish communication connection with reader, and set baud
rate for reader.
Input parameter:
nTargetAddress: target addess, such as『192.168.0.1』……
nTargetPort: target communication port, such as『1969』
nHostAddress: host address, such as『192.168.0.2』……
nHostPort: host communication port, such as『5000』
output parameter:
090909RevA|Page 72 of 97