Specifications

Table Of Contents
SDK software development | VI-88R development handbook
Address: RS485 networking address of readerAddress =0 no networking.
Output parameter:
Protected: protection state0- no protect1-protected
return: if function return value is OK, it means read success, otherwise
failure reason.
3.2.5 Read write ISO18000-6C function
3.2.5.1 Identify EPC number of ISO18000-6C tag
apiReturn _stdcall EPC1G2_ReadLabelID(HANDLE hScanner, BYTE mem, int
ptr, BYTE len, BYTE *mask, BYTE *IDBuffer, int *nCounter,int Address);
apiReturn _stdcall Net_EPC1G2_ReadLabelID(SOCKET hSocket, BYTE mem,
int ptr, BYTE len, BYTE *mask, BYTE *IDBuffer, int *nCounter);
Function: to read EPC number of all eligible readable tag in antenna
radiation field.
Input parameter:
hSacnner/hSocket: reader communication port handle
mem: select memory bank
0 Passwrod
1
EPC
2
TID
3
User
ptr: start address of mask(unit:Bit)
090909RevA|Page 92 of 97