Do not touch the charging connector/battery and the patient simultaneously when charging/using.
Warning
The safety of usage during pregnancy or menstruation has not been determined.
Electrode positioning and stimulation parameters’ setting should be conducted by professionals. If you keep
feeling pains or rash, please stop using this product.
Please do not position the electrode in the area of malignant neoplasms, neck arteries (throat) or thrombus.
Be careful if the electrode positioning areas show following situations:
Bleeding trend caused by serious trauma;
Muscle training might cause disorder of rehabilitation of a recent surgery;
Electrode positioning areas are not sensitive enough.
Please use with caution when the arteries of used area show partial occlusion, when the patient has vascular
atrophy because of hemodialysis, or when the vascular system shows instability.
Please use with caution when the output current density exceeds 10mA/cm
2
(r.m.s).
Please use with caution if the used areas have structural deformity.
This product should be conducted by doctors.
Patients should keep stable and not move while using this unit.
Patients should not move the electrode or be touched while using this unit.
Please stop using this product if the body shows any physical abnormality.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
FCC warning:
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's
authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet general RF exposure requirement. The device can be used in portable
exposure condition without restriction.