824-033 15
Removing
and Installing Pump
WARNING
INJECTION
HAZARD
T
o reduce the risk of serious injury
,
whenever you are instructed to relieve
pressure, follow the
Pressure Relief
Procedure
on page 7.
Removal
See Fig. 12.
1.
Flush pump, if possible. Relieve pressure again.
Stop pump with piston rod in lowest position, if
possible.
2.
Disconnect drain tube (101) from pump (39) and
suction tube (42).
3.
Remove suction tube (42); hold wrench on pump
intake valve (223) to keep pump from loosening.
4.
Remove hose (47).
5.
Push retaining spring (35) up and push out
pin (20).
6.
Loosen locknut (38) and unscrew pump from
bearing housing (27).
Installation
See Fig. 12 and 13.
1.
Screw displacement pump into bearing
housing (27) until pin hole in connecting rod as
-
sembly (29) and displacement rod (A) align. Install
pin (20).
2.
Continue to screw pump into bearing housing until
top threads of pump cylinder are flush with face of
bearing housing and outlet nipple (75) is straight
back. Push retaining spring (35) into groove
around connecting rod. T
ighten locknut (38) to 70
ft-lb (95 N.m).
WARNING
MOVING P
ARTS HAZARD
Be sure the retaining spring (35) is firmly
in the groove of the connecting rod, all
the way around, to prevent it from work
-
ing loose due to vibration.
If the pin works loose, it or other parts could break
of
f due to the force of the pumping action. These
parts could be projected through the air and result
in serious bodily injury or property damage, includ
-
ing damage to the pump, connecting rod or bearing
housing.
CAUTION
If the locknut (38) loosens during operation, the
threads of the bearing housing (27) will be damaged.
Be sure to tighten the locknut firmly
.
3. T
ighten packing nut/ wet-cup just enough to stop
leakage, but no tighter
. Fill wet–cup/packing nut
1/3 full with Graco TSL.
7392A
27
Fig. 12
42
223
47
35
20
101
A
39
38
07393A
Fig. 13
1
29
35
27
38
Face
of bearing housing
1
75
2
T
orque to 70 ft–lb (95 N.m)
2
20