Technical data
Before doing this procedure, follow the Pressure
Relief Procedure Warning on page 13 to reduce
the risk of an injection injury, injury from moving
For checking armature, motor winding and brush elec-
trical continuity.
setup
Remove the drive housing from the sprayer as des-
cribed in “Drive Housing Replacement”, Steps l-6,
page 29.
Remove the pressure control cover and screws, the
motor cover, the fan cover (FI, and the inspection
covers (J). See Fig 7.
Disconnect the two leads from the motor to the bridge
KICW. See Fig 8 and 9.
Armature Short Circuit Test
Quickly turn the motor fan by hand.
lf there are no
shorts, the motor will coast two or three revolutions
before coming to a complete stop.
If the motor does not spin freely and resists rotation, the
armature is shorted and the motor must be replaced.
See page 36.
Armature, Brushes, and Motor Wiring Open
Circuit Test (Continuity)
Connect the two black motor leads together with a test
lead.
Turn the motor fan by hand at about two revolutions
per second.
If there is uneven or no turning resistance, check the
following: a1 broken brush springs; b) broken brush
leads; c) loose brush terminal screws; d) worn brushes;
e) broken motor leads; f) loose motor lead terminals.
Repair parts as needed. See page 22.
If there is still uneven or no turning resistance, replace
the motor. See page 30.