Specifications
47
Wisdom 3 DC Manual
© 2002 Design, 2011 Doc. No. 12-5274-r01 (8/31/11)
SPECIFICATIONS
NO DECOMPRESSION MODEL
Basis:
• Modied Haldanean Algorithm
• 12 tissue compartments
Data Base:
• Diving Science and Technology (DSAT) - Rogers/Powell
Performance:
• Tissue compartment halftimes (mins.) Spencer’s “M” values
5, 10, 20, 40, 80, 120, 160, 200, 240, 320, 400, 480
• Reciprocal subsurface elimination
• 60 minute surface credit control for compartments faster than 60 minutes
• Tissue compartments tracked up to 24 hours after last dive
Decompression Capabilities:
• Decompression stop ceilings at 10, 20, 30, 40, 50, 60 ft
(3, 6, 9, 12, 15, 18 m)
Altitude Algorithm:
• Based on NOAA tables
Oxygen Exposure Limits:
• Based on NOAA tables
SURFACE MODES / SCREENS
• Activation/Diagnostic
• Time/Wet
• Time to Fly / Desat Countdowns
• Data (Air, Nitrox, Gauge)
• Plan (Air, Nitrox)
• Last (most recent dive data)
• Log (3 screens)
• History
• Simulator (demo dives)
• Set 1 (Basics):
• Operating Mode (Air, Nitrox, Gauge)
• PO2 Alarm Value (1.20 to 1.60 ATA)
• FO2 Level (21 to 50 %)
• FO2 50% Default (On/Off)
• Set 2 (Alarms):
• All Alarms (On / Off)
• Ascent Alarm (On / Off)
• Max Depth Alarm (On / Off)
• Max Depth Alarm Value (30 to 330 ft / 9 to 99 m)
• Turn Pressure Alarm (On / Off)
• Turn Pressure Alarm Value (1000 to 3000 psi / 69 to 205 bar)
• End Pressure Alarm (On / Off)
• End Pressure Alarm Value (300 to 1500 psi / 20 to 104 bar)
• Reserve Dive Time Alarm (On / Off)
• Reserve Dive Time Alarm Value (1 to 30 min)
• Deco Alarm (On / Off)
• PO2 Alarm (On / Off)
• Set 3 (Utilities):
• Wet Activation (On / Off)
• Units of Measure (Imperial / Metric)
• Sampling Rate (15 / 30 / 60 min)
• Deep Stop (On / Off)
• Set 4 (Time):
• Hour Format (12 / 24)
• Time (Hour, Minute)
• Date (Year, Month, Day)