Instructions / Assembly

14
6.
Remove the bump stopper holder with a narrow-tipped tool.
Bump stopper holder
* Reassemble by carrying out the removal procedure in reverse.
Replacement of the plate and the plate tension spring (RD-M986)
CAUTION
Always ensure that the lever switch is in the OFF position before starting work.
If operating the lever switch while the plate unit cover is removed, press the switch stabilizer with your finger so that it does not
fly out.
ON
Switch stabilizer
OFF