Instruction manual

17
The drain hose must be put below the copper pipe. Put to-
gether the refrigerant pipe, drain hose and the connecting wire
of indoor and outdoor units. Wrap them with binding belt. The
pipes can be arranged towards five directions (back, right, left,
down and left-back). Bind the pipes with binding belt from the
place closest to the elbow (The overlap of the binding should
be 1/2 of the width). Bind the pipes from 1 cm inside of the unit,
if you direct the pipes from the left side.
2-5 Arrangement of Pipes
Front
Left
Left back
Down
Back
Right
Cut off this part
directing pipes
toward left side
1cm
Cut off this part
when directing
pipes to right side
Cut off this part
when directing
pipes down ward
Installation of Indoor Unit
Pass the pipes through the wall, hoist the unit on the installation plate and fix the lower
part with a hook.
Install the wall-through bushing
sheath at suitable place
Wall-through bushing
Attention! Do not
raise the drain hose
Installation plate