Shinepal Electronics Co., Ltd www.shinepal.com GSM Multi-media Message Alarm SP711 Operation Manual Shinepal Electronics Manufacturing Co., Ltd Factory address: FuYuan Industrial City, XiXiang BaoAn District ShenZhen City China 518126 Michael Yang Sales Manager Website: www.shinepal.com Call: (86-755) 27809392 Fax: (86-755) 27809392 Web: www.Shinepal.com MSN: shinepal@live.cn Email: shinepal2008@gmail.
Shinepal Electronics Co., Ltd www.shinepal.com Contents Quick Programming ..................................................................... 2 1. General Information................................................................. 4 1-1 Introduction ....................................................................... 4 1-2 Features ............................................................................ 5 1-3 About the Console...............................................................
Shinepal Electronics Co., Ltd www.shinepal.com 1. Insert SIM card, which MMS is activated, without PIN code SIM Card Holder 2. Select location where signal strength is strong for communication, mounts the console, and adjust camera lens to proper position. 3. Plug in power, +6V, and turn on. Console sounds a beep and 3 beeps around 15 seconds later to indicate system is ready. If 3 beeps not heard, remove the power, check, re-insert the SIM, and re-power after 3 minutes. 4.
Shinepal Electronics Co., Ltd www.shinepal.com Confirmation: user will receive a SMS for confirmation as “M:#0932345678, 0935111111” to indicate programming is successful. Send“000000M” SMS to console phone number Confirmation: user will receive a SMS for confirmation as M-deleted E: To Program Email Address Send“000000Ejuly@yahoo.com,gsm.car.alarm@hotmail.com”SMS to console phone number Confirmation: user will receive a SMS for confirmation as “E:car_alarm@yahoo.com, gsm.car.alarm@hotmail.
Shinepal Electronics Co., Ltd www.shinepal.com function) can use their mobile’s AV and mailbox function to back up the image information (to avoid the destroy of evidences), can real-time receives the alarm messages from any remote location by the AV Monitor devices or monitoring the real-time voice and image from the site for immediate identification. It meets various demands from sectors of household, office, factory, stores….etc.
Shinepal Electronics Co., Ltd www.shinepal.com Microphone Video output Power switch Serial port Power socket 1-4 Package List 1)Standard accessories: a) Consol x 1 e) Antenna x 1 b) Power adaptor x 1 f) Remote Con. X2 c) Rechargeable battery x 1 g) Instruction Manual x 1 d) Universal mounting kit x 1 h) Warranty card x 1 2)Options: a) Enhanced antenna b) Remote con.
Shinepal Electronics Co., Ltd www.shinepal.com 2. Operation 2-1 Major Function 2-1-1 Active reviewing function User can supervise the site by calling the console or sending SMS to console. Instructions are as follows. A. By Calling Make sure the feature of MMS is activated for both caller and the console. You just call the console phone number, and console will pick up, confirm, and hang up the call.
Shinepal Electronics Co., Ltd www.shinepal.com 2-2 Commands You must well know the commands in the table to operate the system Function Command N E Program password Program receiver email address Command M S Program H emergency A alarm receiver D Check System Settings Function Program receiver phone number(s) 1: enable strobe 0: disable strobe 1: Activate 0: Release T Listen-in C Default settings Ext.unit U alarming(reserved func.
Shinepal Electronics Co., Ltd www.shinepal.com 2-2-1 N: To Program Password z To change default password 000000 to preferable code, 111111 Send“000000N111111”SMS to console phone number Confirmation: user will receive a SMS for confirmation as N: 111111 Password is not necessary if operate or program the system from administrator’s mobile phone; it is mandatory for other programmed users. Password is located at the front of any command list if programmed user is intending to operate or program the system.
Shinepal Electronics Co., Ltd www.shinepal.com z To deactivate or delete the panic alarm receiver(s), Send:”000000H” SMS to console phone number Confirmation: user will receive a SMS for confirmation as H-Deleted to indicate programming is successful. Note: a.119 is local emergency line and should be authorized by related department, such as police station, before programmed. b. Strongly recommend not to program receivers who live within same premise.
Shinepal Electronics Co., Ltd www.shinepal.com Confirmation: administrator will receive a SMS for confirmation as:factory reset After resetting the system, system should be restarted and all the remote units should be registered to the system again before using. Try not to use this setting together with other setting operations, better do it independently.
Shinepal Electronics Co., Ltd www.shinepal.com Within transmission range, press and hold the button for 3 seconds to initiate emergency alert. If it is answered the monitor unit will broadcast the pre-record voice to give the warning messages. 2-3-2 Enrollment If you are not able to operate the remote control unit(s) normally after system resetting or adding new one(s), you need to re-enroll the remote control unit (s) to system. Instruction is shown as follows.
Shinepal Electronics Co., Ltd www.shinepal.com 3. Notes 3-1 Location for the System ⑴ Selecting proper location for system installation, you should check the GSM/GRRS signal before installing. You may use your mobile phone with signal strength indicator to check if signal strength of location is strong or not. ⑵ Electricity power, AC110/220V, should be easy to access. ⑶ System is designed for indoor application, not for outdoor.
Shinepal Electronics Co., Ltd www.shinepal.com Q2. The remote control unit doesn’t work. A2: Check if battery or the remote control unit fails. If not, reboot the system to solve the question. If problem still exist, re-enroll the remote control unit to the system. Q3. System is not working A3: Check if system is in testing mode, the bill of console telecommunication paid, or PIN for the SIM card does not disabled. If none of above condition, reboot the system.
Shinepal Electronics Co., Ltd www.shinepal.com 3-7 About Heat Detection Fig-4 Face, elbow, and arm have stronger heat radiation than lower potion of human body. If location is higher than a human height, console should adjust downward to keep zone A of lens in function. If location is lower than human height, no adjustment is needed.
Shinepal Electronics Co., Ltd www.shinepal.com 主頁 Homepage IP 地址 IP address http://mmsc.nwmobility.com:8002 192.168.111.1 用戶名稱 Login name 密碼 Password 端口號 IP Port 9201 連結方式 持續連結 認證類型 普通 安全保護 關 explain of the short message: 1: “ 000000” is the default password of host monitor; 2: “ g” is command character; 3: “ http://mmsc.nwmobility.com:8002” is the Homepage,some times call the MMSC URL “8002” as the http port ,when the port is “80”,it can be ignored . 4: “192.168.111.