Instruction manual

Shinepal Electronics Co., Ltd
www.shinepal.com
Confirmation: administrator will receive a SMS for confirmation asfactory reset
After resetting the system, system should be restarted and all the remote units should be registered to the system
again before using.
Try not to use this setting together with other setting operations, better do it independently.
2-2-11 U: SMS extension unit alarming (reserved function for future version)
z If you use the monitor extension units, #1for the room, #2 for the warehouse, operate as follows
Send “000000U1Room Alarm, 2warehouse alarm” SMS to console phone number
Confirmation: administrator will receive a SMS for confirmation as “u1room alarm ,2warehouse alarm” to indicate
programming is successful.
z delete the alarm contents
Send “000000U” SMS to console phone number
Confirmation: administrator will receive a SMS for confirmation as “U—deleted”
NoteOne master unit can max. connected with 8 extension units, Try not to use this setting together
with other setting operations, better do it independently.
2-2-12 J1/J0 320X240/480 X320 pixels
Console default pixels is 320X240
Send “000000J0” SMS to console phone number
Confirmation: administrator will receive a SMS for confirmation as “pixels 320X240”
to indicate programming is successful.
2-3 Remote Control Unit
2-3-1 Buttons
Button 1: Activation
You should operate the remote control unit within 100 meters, transmission range, to activation the system.
Once the button pressed, the console will sound continuous high-low beeps, and system enter armed mode
after 1 minute.
Button 2: Release
You should operate the remote control unit within 100 meters, transmission range, to release the system. Once
the button pressed, the console will sound a long beep, and system enter disarmed mode.
Button 3: Testing
You should operate the remote control unit within 100 meters, transmission range, to release the system. Once
the button pressed, the console will sound beep a twice, and system enter disarmed mode. If press and hold
the button for 3 seconds, system will enter or exit factory testing mode. Testing is only for factory inspection
purpose, not for end user.
Button 4: Emergency Call
4. Emergency call 3. Testing
2. Release 1. Activation