Instruction manual
Shinepal Electronics Co., Ltd 
www.shinepal.com 
Confirmation: administrator will receive a SMS for confirmation as:factory reset 
After resetting the system, system should be restarted and all the remote units should be registered to the system 
again before using. 
Try not to use this setting together with other setting operations, better do it independently. 
2-2-11 U: SMS extension unit alarming (reserved function for future version) 
z  If you use the monitor extension units, #1for the room, #2 for the warehouse, operate as follows: 
Send “000000U1Room Alarm, 2warehouse alarm” SMS to console phone number 
Confirmation: administrator will receive a SMS for confirmation as “u:1room alarm ,2warehouse alarm” to indicate 
programming is successful. 
z  delete the alarm contents 
Send “000000U” SMS to console phone number   
Confirmation: administrator will receive a SMS for confirmation as “U—deleted” 
Note:One master unit can max. connected with 8 extension units, Try not to use this setting together 
with other setting operations, better do it independently. 
2-2-12 J1/J0 320X240/480 X320 pixels 
Console default pixels is 320X240 
Send “000000J0” SMS to console phone number   
Confirmation: administrator will receive a SMS for confirmation as “pixels 320X240” 
to indicate programming is successful. 
2-3 Remote Control Unit 
2-3-1 Buttons 
Button 1: Activation 
You should operate the remote control unit within 100 meters, transmission range, to activation the system. 
Once the button pressed, the console will sound continuous high-low beeps, and system enter armed mode 
after 1 minute. 
Button 2: Release 
You should operate the remote control unit within 100 meters, transmission range, to release the system. Once 
the button pressed, the console will sound a long beep, and system enter disarmed mode. 
Button 3: Testing 
You should operate the remote control unit within 100 meters, transmission range, to release the system. Once 
the button pressed, the console will sound beep a twice, and system enter disarmed mode. If press and hold 
the button for 3 seconds, system will enter or exit factory testing mode. Testing is only for factory inspection 
purpose, not for end user. 
Button 4: Emergency Call 
4. Emergency call 3. Testing 
2. Release   1. Activation   










