2-2 Commands
You must well know the commands in the table to operate the system
Command
Function Command
Function
N
Program
password
M
Program receiver phone
number(s)
E
Program receiver
email address
S
1: enable strobe
0: disable strobe
H
Program
emergency
alarm receiver
A
1: Activate
0: Release
D
Check System
Settings
T Listen-in
U
Ext.unit
alarming(reserved
func.)
C Default settings
1-7 Supervise the Site
J1/J0 320X240/480X320pixels
SMS format: (Password)+Command1+Setting1+Command2+Setting2+……
In each SMS, you can combine commands to perform single or multi programming. Beware of that previous setting
will be overlapped and invalid by new setting automatically.
Cautions:
perform programming: If administrator and user(s) are assigned, password is not required for administrator
and necessary for other user(s).
SMS should be keyed either in English or Chinese. Maximal up to 140 characters for English and 70 characters
for Chinese compose the SMS command list, which includes characters, numbers, and symbols.
While programming email address, only lowercase is decodable for email address entry.
Other than “ , “ (comma) is used as a separator in a command list, “ “(space) and “ * “ (asterisk) can be used
as separators as well.
Password is composed of 6 digit numbers, 0-9.
Maximal up to 5 receiver phone numbers, 3 email addresses, and 5 panic alarm receivers can be programmed
respectively.
Even though separator is not a must during two different commands, we strongly recommend to use separator
between the commands. In contrast, separator is mandatory for the setting, such as phone number, after the
command if setting is more than one.
While programming email address, only English letter, number, and underscore are acceptable. Semicolon, “ ; ”,
is used as prefix and suffix of command list for email address programming. Comma, “ , , is used to divide
every email address if email address for programming is more than one and used to close email address entry.
Max. up to 3 email addresses can be stored into system; newly programmed email address will clear and
overlap previous email address settings automatically. Format is shown as follows.
Eemail,email,email,;
If you program phone set, not mobile phone, as receiver, the system will just send vocal alert message instead
of the pictures of premise when alarm occurs.
Refer to the following examples for detailed instruction for programming.
(System Default Password: 000000