9.MAINTENANCE PLAN
9.1 General
This chapter describes the maintenance plan of Shinko OHT system.
9.2 Maintenance plan
It consists of following four category;
(1) Daily check (during the normal operation)
(2) Semi-annual maintenance
(3) Every one year maintenance
(4) Every two years maintenance
9.2.1 Daily check
It is not a maintenance but a daily check during the normal operation. By the experience of daily
operation, abnormal noise or vibration can be detected. Important check points are as follows:
(1) Vehicle
(1-a) Be careful at the movement of each axis (i.e. X-axis (running), Y-theta-axis, and Z-
axis(up-down) ). If abnormal noise or vibration might be happened, it should be
recorded and it simply increased, maintenance shall be rescheduled.
(1-b) See the surface (such as cover, connection point), and check whether there is a dirt or
tear.
(1-c) See the surface of the hoisting belts, and check whether there is a dirt or wound.
(2) Rail
(2-a) Listen to the sound of rail and vehicle when it travels on the joint portion of the rail.
(3) Power Supply Panel
(3-a) See the ampere-meter and it’s value is within the predetermined value range.