DIN rail mounting type indicating controller DCL-33A
No.DCL31E1 .
To prevent accidents arising from the misuse of this controller, please ensure the operator using it
receives this manual.
Caution
•
This instrument should be used according to the specifications described in this manual.
If it is not used according to the specifications, it may malfunction or breakdown.
•
Be sure to follow the warnings, cautions and notices. If not, serious injury or accidents may occur.
•
The specifications of the DCL-33A and the contents of this instruction manual are subject to change
without notice.
•
Care has been taken to assure that the contents of this instruction manual are correct, but if there are
any doubts, mistakes or questions, please inform our sales department.
• Be sure to check that the power is turned off when cleaning this instrument.
• Use a soft and dry cloth when cleaning the instrument.
(If paint thinner is used, it might deform or tarnish the unit.)
• As the display section is vulnerable, do not strike or scratch it with a hard object.
•
Any unauthorized transfer or copying of this document, in part or in whole, is prohibited.
•
Shinko Technos is not liable for any damages or secondary damages incurred as a result of
using this product, including any indirect damages.
1. Model name
1.1 Model name
DCL-3 3 A-
/ ,
Series name: DCL-300 (W22.5 x H75 x D100mm)
Control action
3
PID
Alarm A
Alarm action is selectable by key operation *1
Control output
R
Relay contact: 1a
S
Non-contact voltage (for SSR drive): 12
+2
,
-0
Vdc
A
DC current: 4 to 20mAdc
Input
M
Multi-range *2
Option
W (5A)
Heater burnout alarm
CT rated current: 5A
W (10A) CT rated current: 10A
W (20A) CT rated current: 20A
W (50A) CT rated current: 50A
C5 Serial communication Based on EIA RS-485
*1: Alarm action (9 types and no alarm) and Energized/Deenergized are selectable by key operation.
*2: Thermocouple, RTD, DC current and DC voltage are selectable by key operation.
1.2 How to indicate model name label
Model name label is on the right side of the case and the bottom of the inner assembly.
In the case of Heater burnout alarm output, CT rated current value is written in the bracket ( ).
Model name ----------------------------------
Option ------------------------------------------
Option ------------------------------------------
Instrument No. (Inner assembly only)--
DCL-33A-R/M Relay contact output/ Multi-range input
Heater burnout alarm output
W (20A)
No. XXXXXX