Use and Care Manual
-25-
Model W1844 (For Machines Mfd. Since 5/17)
SERVICE
Troubleshooting
This section covers the most common problems and corrections with this type of
machine. WARNING! DO NOT make any adjustments until power is disconnected and
moving parts have come to a complete stop!
Motor & Electrical
SYMPTOM POSSIBLE CAUSE
POSSIBLE SOLUTION
on
Machine does not
start or a breaker
trips immediately
after startup.
1. Switch disabling key removed.
2. Incorrect power supply voltage or circuit
size.
3. Power supply circuit breaker tripped or
fuse blown.
4. Wiring open/has high resistance.
5. Start capacitor at fault.
6. ON/OFF switch at fault.
7. Motor at fault.
1. Install switch disabling key.
2. Ensure correct power supply voltage and circuit
size.
3. Ensure circuit is sized correctly and free of shorts.
Reset circuit breaker or replace fuse.
4. Check/x broken, disconnected, or corroded wires.
5. Test/replace.
6. Test/replace.
7. Test/repair/replace.
Machine stalls or is
underpowered.
1. Motor overheated.
2. Dust collection ducting problem.
3. Filter element clogged/at fault.
4. Dust collector undersized.
5. Motor wired incorrectly.
6. Run capacitor at fault.
7. Centrifugal switch at fault.
8. Motor bearings at fault.
1. Allow motor to cool.
2. Clear blockages, seal leaks, use smooth-wall duct,
eliminate bends, close other branches.
3. Clean/replace filter (Page 23).
4. Move closer to machine/redesign ducting layout/
upgrade dust collector.
5. Wire motor correctly (Page 28).
6. Test/replace.
7. Adjust/replace centrifugal switch if available.
8. Test by rotating shaft; rotational grinding/loose
shaft requires bearing replacement.
Machine has
vibration or noisy
operation.
1. Motor or component is loose.
2. Motor mount loose/broken.
3. Machine is incorrectly mounted to wall.
4. Motor fan is rubbing on fan cover.
5. Motor bearings are at fault.
1. Inspect/replace stripped or damaged bolts/nuts,
and re-tighten with thread-locking fluid.
2. Tighten/replace.
3. Tighten/replace mounting hardware (Page 16).
4. Replace dented fan cover; replace loose/damaged
fan.
5. Test by rotating shaft; rotational grinding/loose
shaft requires bearing replacement.
Troubleshooting