SL WASH 350 RGBW LED Luminaire
Showline Offices Dallas 10911 Petal Street Dallas, TX 75238 Tel: +1 214-647-7880 Fax: +1 214-647-8030 Auckland 19-21 Kawana Street Northcote, Auckland 0627 New Zealand Tel: +64 9 481 0100 Fax: +64 9 481 0101 Asia Unit C, 14/F, Roxy Industrial Centre No. 41-49 Kwai Cheong Road Kwai Chung, N.T., Hong Kong Tel: +852 2796 9786 Fax: +852 2798 6545 Europe Rondweg zuid 85 Winterswijk 7102 JD The Netherlands Tel: +31 (0) 543-542516 www.philips.
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual IMPORTANT INFORMATION Warnings and Notices When using electrical equipment, basic safety precautions should always be followed including the following: a. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. b. Do not use outdoors. c. Do not mount near gas or electric heaters. d. Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. e.
Installation & User’s Manual SL WASH 350 RGBW LED Luminaire TABLE OF CONTENTS Showline Offices......................................................................................................................................Inside Front Cover IMPORTANT INFORMATION Warnings and Notices......................................................................................................................................................... 1 Additional Resources for DMX512..................................
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual HSIC Mode ............................................................................................................................................................................... HSIC Group Modes .................................................................................................................................................................. SL WASH 350 RGBW LED Luminaire DMX Timing Channel Detail............................
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual PREFACE 1. About this Manual The document provides installation and operation instructions for the following products: • SL WASH 350 RGBW LED Luminaire Please read all instructions before installing or using this product. Retain this manual for future reference. Additional product information and descriptions may be found on the product specification sheet.
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual SL WASH 350 RGBW LED LUMINAIRE OVERVIEW 1.
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual LCD Display / Menu System Edit a Preset Edit a Chase Home (menu settings) DMX512 Addressing Return to Main Screen LCD Display SL WASH 350 DOWN Arrow Button LEFT Arrow Button UP Arrow Button RIGHT Arrow Button CHECK MARK (Accept) Button NOTE: Menu rotates with orientation of luminaire and menu buttons are always in the same position (with rotation of menu) To rotate menu 180 degrees from current orientation, press and hold the two cen
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual INSTALLATION AND SET UP 1. Power Requirements The SL WASH 350 RGBW LED Luminaire operates on AC input voltages from 100 to 240 VAC. WARNING! This unit does not contain an ON/OFF switch. Always disconnect power input cable to completely remove power from unit when not in use. AC Power Operation When connected to an AC source, the unit operates on 100 to 240 volts AC (+/- 10%, auto-ranging). The luminaire contains an auto-ranging power supply.
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual 2. Connecting Power Units can be powered in one of two ways: • Direct connection to a AC power source using an AC input cable. For wiring of AC input connector, refer to "Connecting SL WASH 350 RGBW LED Luminaires to AC Power" below. • Connection from the AC output of another SL WASH 350 RGBW LED Luminaire. When using this method, it is very important not to connect any other type of equipment device.
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual 3. Connecting to the DMX512 Network Basic DMX512 installation consists of connecting multiple SL WASH 350 RGBW LED Luminaires together (up to 32 luminaires) in "daisy-chain" fashion. A cable runs from the control console (or DMX512 control source) to the DMX connector on the first SL WASH 350 RGBW LED Luminaire.
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual 4. Mounting Luminaire SL WASH 350 RGBW LED Luminaires are provided with the ability to hang via truss hooks, clamps, etc. (sold separately) or floor mounted (sitting on fixture base). Securely attach a hook, clamp, etc. to each Omega Mount (two supplied with unit). Attached the Omega Mounts to the luminaire base as illustrated in Figure 7 via the Camlocks.
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual OPERATION AND PROGRAMMING 1.
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual .
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual Step 6. Press the Check Mark button to save the preset. You will be asked to confirm your saving operation. Step 7. The preset is now saved and can be recalled via the menu or DMX. Color Filter Color filters are 43 factory made colors that utilize the Harmonize Color Calibration system (refer to "Harmonize Color Calibration" on page 19 for more information). They can be recalled via the menu system or DMX.
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual To edit and save a Step: Step 1. Select Edit Step or New Step from the Edit User Chase menu. Step 2. The top left field indicates the preset or color filter to be used for the step. When set to OFF no preset or color filter is to be used. Use the left and right buttons to scroll through all presets and color filters. Step 3. Use the Up and Down keys to scroll through the output parameters.
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual Table 6: Strobe / Timing Parameters Parameter Description Master Intensity Overall fixture output intensity level. Strobe: X Strobe mode and rate value settings following DMX map (see DMX CONTROL for details). Duration The time each strobe flash remains ON. Intensity Timing The time used to change intensity values when running a chase. Color Timing The time used to change color values when running a chase.
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual Settings/General Use the Up and Down buttons to select parameters and the Left and Right buttons to assign the different general fixture settings. When finished, press the Check button to exit the menu level. The adjustable parameters are described in Table 9. Table 9: General Level Parameters Parameter Description Power-Up Select the action of the fixture when the unit is powered ON.
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual Settings/DMX Control Channel DMX configuration options are available in the DMX Control Channel menu. Use the Up and Down buttons to select parameters and the Left and Right buttons to assign the fixture's DMX settings. When finished, press the Check button to exit the menu level. The adjustable parameters are described in Table 12.
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual Password (PassPIN) The Password menu item will display an Enter PassPIN dialog box. Use the Up Down Left Right buttons to enter a PIN code matching the codes assigned in the Settings/Security menu to toggle the current security level. Status The Status screen displays the current value of the master intensity and each LED of the luminaire. The number of pixels will vary depending upon fixture type.
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual 4. Harmonize Color Calibration Harmonize is a proprietary, advanced LED color matching system, consisting of 3 correction modules: RGB, RGBW and Cool White/Warm White. Every Showline fixture undergoes rigorous testing to provide you with consistent control of color and intensity as well as output of the highest quality.
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual 6. Master / Slave Operational Mode The Master / Slave Operational Mode allows one SL WASH 350 RGBW LED Luminaire to act as the "Master" unit and all other connected units are controlled by this unit. When a unit is set to "Slave" mode, it will only listen to and follow any commands sent from a "Master" unit. Only one "Master" unit is allowed in this type of operation. To setup a master / slave network: Step 1.
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual DMX CONTROL This section contains information for operating the luminaire using DMX control in 16-bit, 8-bit, Simple RGBW 8bit, or HSIC (Hue, Saturation, Intensity and Color Correction) modes. For Menu options and detailed information, see "LCD Display and Menu System" on page 11. Note: These tables assume a DMX start address of 1.
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual Table 15: DMX Channel Mapping (16-Bit Mode) CONTINUED FROM PREVIOUS PAGE 7 Color Presets 0 - 255 0 - 100% 0 CF_0_Color OFF DMX 69 - 70 CF_1_White 10000K DMX 71 - 72 CF_2_White 8000K DMX 73 - 74 CF_3_White 6500K DMX 75 - 76 CF_4_White 5600K DMX 77 - 78 CF_5_White 5000K DMX 79 - 80 CF_6_White 4500K DMX 81 - 82 CF_7_White 4000K DMX 83 - 84 CF_8_White 3200K DMX 85 - 86 CF_9_White 3000K DMX 87 - 88 CF_10_White 2700K DMX 89 - 90 CF_11_Moroccan Pi
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual Table 15: DMX Channel Mapping (16-Bit Mode) 8 Strobe 0 - 255 0 - 255 0 - 100% 0 - 100% 0 Controls strobe operations as follows: Open = DMX 0 - 2 Closed = DMX 3 - 5 Slow Rand = DMX 6 - 7 Med Rand = DMX 8 - 10 Fast Rand = DMX 11 - 12 Strobe Range = DMX 13 - 127 (fastest) Pulse + Slow Rand = DMX 128 - 129 Pulse + Med Rand = DMX 130 - 131 Pulse + Fast Rand = DMX 132 - 133 Pulse + Range = DMX 134 - 191 Pulse - Slow Rand = DMX 192 - 193 Pulse -
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual 2. 16-Bit Group Modes Table 16 provides DMX channel mapping of all DMX512 control values when the SL WASH 350 RGBW LED Luminaire is operated in various 16-bit DMX512 Group Control Modes.
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual 3. 8-Bit RGBW Mode Table 17 provides DMX channel mapping of all DMX512 control values when the SL WASH 350 RGBW LED Luminaire is in 8-bit DMX512 mode (as set by the luminaire’s menu system).
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual Table 17: DMX Channel Mapping (8-Bit RGBW Mode) CONTINUED FROM PREVIOUS PAGE 6 Color Presets 0 - 255 0 - 100% 0 CF_0_Color OFF DMX 69 - 70 CF_1_White 10000K DMX 71 - 72 CF_2_White 8000K DMX 73 - 74 CF_3_White 6500K DMX 75 - 76 CF_4_White 5600K DMX 77 - 78 CF_5_White 5000K DMX 79 - 80 CF_6_White 4500K DMX 81 - 82 CF_7_White 4000K DMX 83 - 84 CF_8_White 3200K DMX 85 - 86 CF_9_White 3000K DMX 87 - 88 CF_10_White 2700K DMX 89 - 90 CF_11_Morocca
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual Table 17: DMX Channel Mapping (8-Bit RGBW Mode) 7 Strobe 8 Duration 0 - 255 0 - 255 0 - 100% 0 - 100% 0 Controls strobe operations as follows: Open = DMX 0 - 2 Closed = DMX 3 - 5 Slow Rand = DMX 6 - 7 Med Rand = DMX 8 - 10 Fast Rand = DMX 11 - 12 Strobe Range = DMX 13 - 127 (fastest) Pulse + Slow Rand = DMX 128 - 129 Pulse + Med Rand = DMX 130 - 131 Pulse + Fast Rand = DMX 132 - 133 Pulse + Range = DMX 134 - 191 Pulse - Slow Rand = DMX
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual 4. 8-Bit RGBW Group Modes Table 18 provides DMX channel mapping of all DMX512 control values when the SL WASH 350 RGBW LED Luminaire is operated in various 8-bit DMX512 Group Control Modes.
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual 5. Simple RGBW 8-Bit Mode Table 19 provides DMX channel mapping of all DMX512 control values when the SL WASH 350 RGBW LED Luminaire is in Simple RGBW 8-bit DMX512 mode (as set by the luminaire’s menu system).
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual 6. Simple RGBW 8-Bit Group Modes Table 16 provides DMX channel mapping of all DMX512 control values when the SL WASH 350 RGBW LED Luminaire is operated in various Simple RGBW 8-bit DMX512 Group Control Modes.
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual 7. HSIC Mode Table 21 provides DMX channel mapping of all DMX512 control values when the SL WASH 350 RGBW LED Luminaire is in HSIC (Hue, Saturation, Intensity, and Color Correction) DMX512 mode (as set by the luminaire’s menu system).
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual 8. HSIC Group Modes Table 22 provides DMX channel mapping of all DMX512 control values when the SL WASH 350 RGBW LED Luminaire is operated in various HSIC DMX512 Group Control Modes.
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual 9. SL WASH 350 RGBW LED Luminaire DMX Timing Channel Detail Timing channel control improves the timed moves of certain groups of parameters. The SL WASH 350 RGBW LED Luminaire provides timing channels in 16-bit mode (one for intensity time and one for color time) and one timing channel in 8-bit (color and intensity timing combined).
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual Table 23: SL WASH 350 RGBW LED Luminaire Timing Channel Detail DMX 32 6.4 13 33 6.6 34 6.8 7.0 14 36 7.2 37 7.4 15 38 7.6 39 7.8 40 8 16 41 8.2 42 8.4 17 43 8.6 44 8.8 45 9 18 46 9.2 47 9.4 19 48 9.6 49 9.8 21 22 23 24 25 26 27 28 29 30 31 32 DMX CONTROL (unless noted) 35 20 34 = Seconds % Value 50 10 51 10.2 52 10.4 53 10.6 54 10.8 55 11 56 11.2 57 11.4 58 11.6 59 11.
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual Table 23: SL WASH 350 RGBW LED Luminaire Timing Channel Detail % Value 33 34 35 36 37 38 39 40 = Seconds (unless noted) 83 16.6 84 16.8 85 17 86 17.2 87 17.4 88 17.6 89 17.8 90 18 91 18.2 92 18.4 93 18.6 94 18.8 95 19 96 19.2 97 19.4 98 19.6 99 19.
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual Table 23: SL WASH 350 RGBW LED Luminaire Timing Channel Detail DMX 134 54 53 135 55 136 56 57 54 138 58 139 59 55 140 60 141 61 142 62 56 143 63 144 64 57 145 65 146 66 147 67 58 148 68 149 69 59 150 70 151 71 152 72 153 73 154 74 155 75 61 156 76 157 77 62 158 78 159 79 160 80 63 161 81 162 82 64 163 83 164 84 165 85 65 166 86 167 87 66 168 88 169 89 170 90 67
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual Table 23: SL WASH 350 RGBW LED Luminaire Timing Channel Detail DMX 185 105 73 186 106 187 107 (unless noted) 188 108 74 189 109 190 110 75 191 111 192 112 193 113 76 194 114 195 115 77 196 116 197 117 198 118 78 199 119 200 100 79 201 121 202 122 203 123 80 204 124 205 125 81 206 126 207 127 82 208 128 209 129 210 130 211 131 83 212 132 213 133 84 214 134 215 135 216 136
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual Table 23: SL WASH 350 RGBW LED Luminaire Timing Channel Detail = Seconds % Value DMX 236 156 93 237 157 238 158 (unless noted) 239 159 94 240 160 241 161 95 242 162 243 163 244 164 96 245 165 246 5 Minutes 97 247 15 Minutes 248 30 Minutes 249 60 Minutes 250* 60mS 98 99 100 251* 80mS 252* 100mS 253* 100mS 254* 140mS 255* (default) 160mS Note: * DMX values 250 to 255 provide smoothing when using co
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual 10. SL WASH 350 RGBW LED Luminaire RDM Parameter IDs The following tables outline and describe all the RDM parameters IDs associated with SL WASH 350 RGBW LED Luminaires.
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual Table 26: RDM Parameters IDs Get Allowed Set Allowed RDM Parameter IDs Value Comment Implemented Category - Network Management ■ ■ ■ ■ DISC_UNIQUE_BRANCH 0x0001 ■ DISC_MUTE 0x0002 ■ DISC_UN_MUTE 0x0003 ■ PROXIED_DEVICES 0x0010 PROXIED_DEVICES_COUNT 0x0011 COMMS_STATUS 0x0015 Category - Status Collection ■ QUEUED_MESSAGE 0x0020 ■ ■ STATUS_MESSAGES 0x0030 ■ ■ ■ STATUS_ID_DESCRIPTION 0x0031 ■ ■ CLEAR_STATUS_ID
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual Table 26: RDM Parameters IDs Get Allowed Set Allowed RDM Parameter IDs Value ■ RECORD_SENSORS 0x0202 Comment Implemented Category - Dimmer Settings 0x03xx - FUTURE USE Category - Power / Lamp Settings 0x04xx ■ ■ ■ ■ DEVICE_HOURS 0x0400 ■ LAMP_HOURS 0x0401 ■ LAMP_STRIKES 0x0402 ■ ■ LAMP_STATE 0x0403 ■ ■ LAMP_ON_MODE 0x0404 ■ ■ DEVICE_POWER_CYCLES 0x0405 Category - Display Settings 0x05xx ■ ■ DISPLAY_INVERT 0x05
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual Table 28: RDM Manufacturer Specific PIDs for Root Device Get Allowed Set Allowed RDM Parameter IDs Type Length Unit Prefix Min Max Default Description Category - Manufacturer Defined PIDs - Range is 0x8000-0xffdf (See ANSI E1.
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual CLEANING AND CARE WARNING! All cleaning should be performed with power completely removed from the luminaire. Never remove protective covers when luminaire is powered. Wear appropriate protective eye wear and gloves when cleaning the fixture. All service and maintenance, other than described herein, should be performed by a qualified technician or Authorized Service Center. 1.
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual TECHNICAL SPECIFICATIONS 1. SL WASH 350 RGBW LED Luminaire Operational Specifications Source: Beam Angle: Light Output: Color Temperature: Input Voltage (AC): Current (AC): Frequency: Control Protocols: Ambient Temperature: Humidity: Cooling: Weight: Housing: Compliance: IP Rating: RGBW LED Array (19) 8 to 40 Degrees > 5,800 lumens / CRI/CQS: > 90 (RGBW) 2700 - 10000K (user adjustable) 100V to 240V (+/- 10%, auto-ranging) 3.6 Amps (100V) / 1.
SL WASH 350 RGBW LED Luminaire Installation & User’s Manual Notes Sh wline SL WASH 350 RGBW LED Luminaire Dimensions 45