User`s manual

SL WASH 350 RGBW LED Luminaire Main Menu Options 17
SL WASH 350 RGBW LED Luminaire
Installation & User’s Manual
Sh wline
Settings/DMX Control Channel
DMX configuration options are available in the DMX Control Channel menu.
Use the Up and Down buttons to select parameters and the Left and Right buttons to assign the fixture's DMX
settings. When finished, press the Check button to exit the menu level. The adjustable parameters are described in
Table 12.
Settings / LED Group
Select the number of LED groups to control via DMX (see the individual modes contained in "DMX CONTROL" on
page 21 for details).
Settings/Display
Options of the fixture's LCD display can be adjusted in the Display menu.
Use the Up and Down buttons to select parameters and the Left and Right buttons to assign the fixture's DMX
settings. When finished, press the Check button to exit the menu level. The adjustable parameters are described in
Table 13.
Lock Fixture
You can lock all fixture functions, requiring a PIN code to access the menu functions. When you select this menu
item, you are asked to confirm that you wish to lock the fixture. Once locked, all menu items can only be accessed by
entering one of the three PIN codes assigned in the Settings/Security menu. (see "Settings/Security" on page 15 for
more information). The PIN code used to unlock the fixture will only unlock the functionality assigned to that
particular PIN code.
Note: When the fixture is powered off, the Lock Fixture function will be disabled. To assign fixture power-up
security refer to (see "Settings/Security" on page 15 for more information).
Table 12: DMX Setting Parameters
Parameter Description
Dim Response Normal Fixture LEDs dim with a normal response.
Dim Response Incandescent
Fixture LED's dim with an incandescent emulation response. The response to dimming
commands will be slightly delayed at lower intensities.
Dimming Curve Linear
Applies a linear control of the output of the fixture based on the DMX values on the
Intensity Control Channels. See Dimming Curve Selection for more details.
Dimming Curve Square
Applies a square law control of the output of the fixture based on the DMX values on the
Intensity Control Channels. See Dimming Curve Selection for more details.
Dimming Curve S-Curve
Applies an S-Curve control of the output of the fixture based on the DMX values on the
Intensity Control Channels. See Dimming Curve Selection for more details.
Dimming Curve PL-Curve
Applies a dimming curve that follows the Philips Selecon PL series LED Luminaires
control of the output of the fixture based on the DMX values on the Intensity Control
Channels. See Dimming Curve Selection for more details.
Calibration OFF
Toggle Harmonize Color Calibration OFF (see Harmonize Color Calibration for more
information).
Calibration ON
Toggle Harmonize Color Calibration ON (see Harmonize Color Calibration for more
information).
Fan Auto
Fixture fans come on as needed and will still vary in speed, but will not exceed the factory
set minimal noise limit.
Fan Off
Fixture fans will remain off in all circumstances and the fixture will automatically reduce
LED output levels if LED temperatures rise above factory settings.
Table 13: LCD Display Parameters
Parameter Description
Flip Display
Yes - The display will be inverted.
No - The display will not be inverted.
Auto - The display will automatically invert depending upon fixture orientation.
Off Time
Assign a time for the display to automatically turn off after the last button press. A value of
ON will leave the display on indifferently.
Language Select English is the only language currently supported.