9
MASTER mode color table
: (when d;XXX=d:XXX)
NO. Red(%) Green(%) Blue(%) NO. Red(%) Green(%) Blue(%)
1 0 100 0 21 100 0 20
2 0 0 100 22 0 75 100
3 100 0 0 23 0 40 100
4 100 0 100 24 0 15 100
5 100 100 0 25 50 100 0
6 0 100 100 26 25 0 100
7 75 100 0 27 0 100 25
8 40 100 0 28 100 0 50
9 15 100 0 29 0 25 100
10 100 0 75 30 100 0 50
11 100 0 40 31 25 100 0
12 100 0 15 32 50 0 100
13 75 0 100 33 100 0 25
14 40 0 100 34 0 100 50
15 15 0 100 35 100 0 25
16 0 100 75 36 0 50 100
17 0 100 40 37 100 50 100
18 0 100 15 38 50 100 100
19 100 0 80 39 100 100 50
20 100 0 50
Every
color runs
circulary
and
orderly
40 100 100 100
Example: when the 13
th
Step is running, d:xxx = d:085: Red lights up: 75%*85% =64%,
Green lights up: 0%*85%=0%
Blue lights up: 100%*85%=85%.
Maintenance
The operator has to make sure that safety-relating and machine-technical installations are to be inspected
by an expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are to be inspected
by a skilled person once a year.
The following points have to be considered during the inspection:
1. All screws used for installing the device or parts of the device have to be tightly connected and must
not be corroded.
2. There may not be any deformations on housings, fixations and installation spots.
3. Mechanically moving parts like axles, eyes and others may not show any traces of wearing.
4. The electric power supply cables must not show any damages or material fatigue.
The Showtec RGB Theatre Spot requires almost no maintenance. However, you should keep the unit clean.
Otherwise, the light-output will be significantly reduced. Disconnect the mains power supply, and then wipe
the cover with a damp cloth. Do not immerse in liquid. Wipe lens clean with glass cleaner and a soft cloth.
Do not use alcohol or solvents.
The front glass will require weekly cleaning, as smoke-fluid tends to build up residues, reducing the light-
output very quickly.
Please clean internal components once a year with a light brush and vacuum cleaner.
Keep connections clean. Disconnect electric power, and then wipe the DMX and audio connections with a
damp cloth. Make sure connections are thoroughly dry before linking equipment or supplying electric power.
Changing the Lamp
1. Disconnect mains power supply, and allow 15 minutes to cool down. Loosen the 3 screws on the housing.
Gently remove the lamp cover.
2. Follow directions for installing a new lamp, page 6.