User's Manual
Table Of Contents
- Table of Contents
- AD3 Plug-On Transmitter
- WARNING
- AD3 Axient Digital Plug-On Transmitter
- Included Components
- Optional Accessories
- AD3 Transmitter Overview
- Setup
- Setting the AA Battery Type
- Transmitter Controls
- Menu Overview
- Home Screen Display
- Locking the Interface
- IR Sync
- Setting the Frequency Manually
- Updating Firmware
- RF Mute
- Safe Start
- Input Overload
- Input Overload
- Tone Generator
- Matching Audio Levels with Offset
- Menu Item Descriptions
- Specifications
- Mic Offset Range
- Battery Type
- Battery Runtime
- Dimensions
- Weight
- Housing
- Operating Temperature Range
- Storage Temperature Range
- Audio Input
- Connector
- Configuration
- Impedance
- Maximum Input Level
- Preamplifier Equivalent Input Noise (EIN)
- Phantom Power
- High Pass Filter
- RF Output
- Antenna Type
- Impedance
- Occupied Bandwidth
- Channel-to-Channel Spacing
- Modulation Type
- Power
- Specific Absorption Rate (SAR)
- Frequency Bands and Transmitter RF Power
- LICENSING INFORMATION
- Certifications
- Contact Customer Support
Shure Incorporated
15/23
◦
◦
◦
◦
◦
Menu Item Descriptions
Radio Menu
Freq
Press the O button to enable editing of a group (G:) channel (C:) or frequency (MHz). Use the arrow buttons to adjust the
values. To edit the frequency, press the O button once to edit the first 3 digits, or twice to edit the second 3 digits.
Power
Higher RF power settings can extend the range of the transmitter.
Note: Higher RF power settings decrease battery runtime.
Output
Sets the RF output to On or Mute.
On: RF signal is active
Mute: RF signal is inactive
Audio Menu
Phantom
Adds phantom power for condenser microphones. Select +12V or +48V as required by the microphone.
Input Pad/Boost
Adjust the pad to avoid overloading the audio input or add a boost to lowoutput sources. Choose between 12 dB, Off (de
fault), and +12dB.
12 dB: Use with high output sources, such as line levels and point-to-point applications.
Off (default): Use with typical microphones.
+12 dB: Use with low output sources.
HP Filter
High-pass filter. Scroll up to turn on the filter and set the low-frequency rolloff in Hz; scroll all the way down to turn off.
Range: 40 Hz to 240 Hz.
Polarity