User's Manual

Shure Incorporated
15/25
3.
4.
5.
1.
2.
3.
4.
Power on the transmitter.
Press the SYNC button on the receiver.
Align the IR windows between the transmitter and the receiver so that the IR LED illuminates red. When complete,
Sync Success! appears. The transmitter and receiver are now tuned to the same frequency.
Note:
Any change to the encryption status on the receiver (enabling/disabling encryption) requires a sync to send the settings to the
transmitter. New encryption keys for the transmitter and receiver channel are generated on every IR sync, so to request a new
key for a transmitter, perform an IR sync with the desired receiver channel.
Setting the Frequency Manually
The transmitter can be manually tuned to a specific group, channel, or frequency.
Navigate to the Radio menu and select Freq.
Scroll to select G: and C: to edit the group and channel, or select the frequency parameter (MHz). When editing the fre
quency, press enter once to edit the first 3 digits, or twice to edit the last 3 digits.
Use the ∧∨ buttons to adjust the group, channel, or frequency.
Press enter to save, and then press exit when finished.
Updating Firmware
Firmware is embedded software in each component that controls functionality. Periodically, new versions of firmware are devel
oped to incorporate additional features and enhancements. To take advantage of design improvements, you can upload and in
stall new versions of the firmware by using the Shure Update Utility. The Shure Update Utility is available for download from
http://www.shure.com/.