System information

Chapter 23 ‒ Care and Maintenance of Lithium-Ion Rechargeable Batteries
Storing Batteries
When batteries are not going to be used for longer periods of time, they should be stored at an ideal voltage of 3.8 volts to
maintain optimal health. The AXT900 Rackmount Charger has a Storage Mode function that when activated, will charge
or discharge a battery to 3.8 volts.
To avoid degrading battery health, keep the storage temperature range between 10°C to 25°C (50°F to 77°F).
Transportation
The Axient lithium-ion batteries are designed to be transported in either the chargers or in the transmitters. Avoid shipping
loose batteries that are not properly packaged. See other instruction in the Lithium-Ion Rechargeable Battery chapter for
details and requirements for transporting lithium-ion batteries.
Cleaning
If the battery contacts become dirty, you can gently clean them with a small amount of rubbing alcohol and a cotton swab.
Do not pour any liquids, including alcohol, directly onto the battery contacts. Dip the cotton swab into the alcohol, and then
clean the contacts. Be sure to wipe away any excess alcohol from the contacts or other material such as cotton that may
have come loose from the swab.
Inspecting
Periodically inspect each battery for the following:
• cracks
• open seams
• leakage
• damaged, misaligned, or broken contacts
If you see any of these problems while inspecting the battery, do not attempt to charge the battery or use it in a
transmitter. Remove the battery from service and dispose according to local regulations.
145